ASTM-B902 Standard Specification for Compressed Round Stranded Copper Conductors, Hard, Medium-Hard, or Soft Using Single Input Wire Construction

ASTM-B902 - 2013 R18 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification covers stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated conductor assemblies for electrical purposes. These conductors shall be composed of one or more roller shaped or die closed layers of helically laid wires using the single input wire. For stranded conductors, the direction of lay of the outer layer shall be leeft hand and may be reversed or unidirectional/unilay in successive layers. Test for the physical and electrical properties of wires composing conductors made from hard-drawn or medium-hard-drawn wires, uncoated or coated, shall be made before but not after stranding. For the purpose of calculating mass, cross sections, and so forth, the density of the copper shall be taken. The mass and electrical resistance of a unit length of stranded unsealed conductor are a function of the lenght of lay shall be calculated.

ORDER

Price:

$63.00        


Want this as a site license?

Scope

1.1 This specification covers stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use in insulated conductor assemblies for electrical purposes. These conductors shall be composed of one or more roller shaped or die closed layers of helically laid wires using the single input wire (SIW) methodology. (see Note 1 and Explanatory Note 1)

Note 1: Sealed conductors which are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.

1.2 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.

1.2.1 For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard.

1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

compressed; concentric lay stranded conductors; copper; electrical conductors; reverse concentric lay; single input wire; SIW; SIW compressed; stranded copper conductors; unilay;; ICS Number Code 29.060.10 (Wires)

To find similar documents by ASTM Volume:

02.03 (Electrical Conductors)

To find similar documents by classification:

29.060.10 (Wires Including electric rods, busbars, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-B902/B902M-13(2018)

Revision Level

2013 R18 EDITION

Status

Current

Modification Type

Reapproval

Publication Date

Oct. 1, 2018

Document Type

Specification

Page Count

5 pages

Committee Number

B01.04