Standard Test Methods for Hookup Wire Insulation
The following bibliographic material is provided to assist you with your purchasing decision:
These test methods detail the standard procedures for testing hookup wire insulations including all components of the insulation system used on single insulated conductors or an assembly of single insulated conductors such as a cable bundle and harness or flat ribbon cable. The insulating materials include not only the primary insulation over the conductor, but also insulating jackets over shielded constructions. The test procedures covered here shall be performed in the conditions or shall determine the properties, as follows: axial stability (longitudinal change) after thermal exposure; bondability to potting compounds; capacitance; cold bend test; concentricity; crush resistance; dielectric breakdown voltage; dimensions; dry-arc tracking; dynamic cut-through; fluid immersion; high temperature shock; insulation-continuity proof tests; insulation resistance; partial discharge (corona) inception and extinction voltage; relative thermal life and temperature index; strip force; surface resistance; tensile properties; vertical flame test; voltage rating of hook-up wire; voltage withstand test; and wet arc-tracking.
Scope
1.1 These test methods cover procedures for testing hookup wire.
1.2 For the purposes of these test methods, hookup wire insulation includes all components of the insulation system used on single insulated conductors or an assembly of single insulated conductors such as a cable bundle and harness or flat ribbon cable. The insulating materials include not only the primary insulation over the conductor, but also insulating jackets over shielded constructions.
1.3 The test procedures and their locations are as follows:
Keywords
ambient temperature; arcing; arc-propagation; arc-tracking; atmospheric pressure; breakdown voltage; cable; circuit breakers; current limiting; cuts; degradation; dropping apparatus; dry-arcing; electrical insulation; electrolyte; extinction voltage; flame propagation; flame spread; flame test; flammability; hookup wire; insulation thickness; moisture; open-circuit detection; partial discharge; power supply; safe voltage; scintillation; service condition; short-circuit detection; shutdown equipment; track resistant; tracking; transportation vehicles; voltage rating; wet; wire abrasion; wire chafing; wire insulation; Concentricity; Continuity; Dielectric breakdown voltage; Diesel engine cylinder liners; Dimensions; Electrical insulating solids; Electrical resistance/resistivity--insulating materials; Hookup wire; Mercury U-tube method; Permittivity (dielectric constant)--electrical insulating materials; Temperature tests--electrical insulation; Voltage
To find similar documents by ASTM Volume:
10.02 (Electrical Insulation (II): D2518 - latest)
To find similar documents by classification:
29.060.10 (Wires Including electric rods, busbars, etc.)
To find similar documents by Federal Supply Class Code:
FSC 6145 (Wire and Cable, Electrical)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D3032-10
Revision Level
2010 EDITION
Status
Superseded
Modification Type
Revision
Publication Date
March 1, 2010
Document Type
Test Method
Page Count
41 pages
Committee Number
D09.07