ASTM-E1695 Standard Test Method for Measurement of Computed Tomography (CT) System Performance

ASTM-E1695 - 2020(E1) EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Measurement of Computed Tomography (CT) System Performance
ORDER

Price:

$69.00        


Want this as a site license?

Scope

1.1 This test method provides instruction for determining the spatial resolution and contrast sensitivity in X-ray and -ray computed tomography (CT) images. The determination is based on examination of the CT image of a uniform disk of material. The spatial resolution measurement is derived from an image analysis of the sharpness at the edge of the disk. The contrast sensitivity measurement is derived from an image analysis of the statistical noise at the center of the disk.

1.2 This test method is more quantitative and less susceptible to interpretation than alternative approaches because the required disk is easy to fabricate and the analysis is immune to cupping artifacts. This test method may not yield meaningful results if the disk image occupies less than a significant fraction of the field of view.

1.3 This test method may also be used to evaluate other performance parameters. Among those characteristics of a CT system that are detectable with this test method are: the mid-frequency enhancement of the reconstruction kernel, the presence (or absence) of detector crosstalk, the undersampling of views, and the clipping of unphysical (that is, negative) CT numbers (see Air Force Technical Report WL-TR-94-4021). It is highly likely that other characteristics as well can be detected with this test method.

1.4 The values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

computed tomography; contrast discrimination; contrast sensitivity; CT; geometrical unsharpness; spatial resolution; ICS Number Code 35.240.80 (IT applications in health care technology)

To find similar documents by ASTM Volume:

03.03 (Nondestructive Testing)

To find similar documents by classification:

11.040.50 (Radiographic equipment Including radiographic diagnostic and therapy equipment Dental, medical and industrial radiographic films, see 37.040.25)

35.240.80 (IT applications in health care technology Including computer tomography)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IPC-A-610
Acceptability of Electronic Assemblies (Hardcopy format)

IPC/EIA-J-STD-001
Requirements for Soldered Electrical and Electronic Assemblies

IEC-60664-1
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests

Document Number

ASTM-E1695-20E01

Revision Level

2020(E1) EDITION

Status

Current

Modification Type

Reapproval

Publication Date

June 20, 2022

Document Type

Test Method

Page Count

13 pages

Committee Number

E07.01