ASTM-B565 Historical Revision Information
Standard Test Method for Shear Testing of Aluminum and Aluminum-Alloy Rivets and Cold-Heading Wire and Rods

ASTM-B565 - 2004 R15 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Shear Testing of Aluminum and Aluminum-Alloy Rivets and Cold-Heading Wire and Rods
ORDER

Scope

1.1 This test method covers the double shear testing of aluminum and aluminum alloy rivets with round, solid shanks and cold-heading wire and rod.2

Note 1: Exceptions to this test method may be necessary in individual specifications or methods for tests for a particular material.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

5.1 This test method is intended solely for the shear testing of rivets and cold-heading wire and rod, and is not generally recommended for the determination of the shear strength of other products. For rivets, this method is limited to rivets having a shank length equal to or greater than 2d.

Note 2: The results of shear tests of specimens machined from products other than wire, rod, and rivets may be greatly dependent upon the orientation of the specimen within the original test material, and the direction in which the force is applied relative to the grain flow in the specimen.4 It is recommended that shear strengths of other products be determined by Test Method B769 for products greater than 0.250 in. (6.4 mm) and Test Method B831 for products less than 0.250 in. (6.4 mm). Shear strengths developed by this test method have been shown to vary from those developed by other methods.4 If Test Method B565 is used for shear testing of other products, variables such as those described in Test Method B769 should be identified and controlled.

5.2 The results of shear tests are dependent upon the relative and absolute lengths of specimen which are sheared out, and those which are supported.4 The results of tests made in accordance with this method should not be directly compared with those determined in other types of tests in which the methods of loading and supporting the specimen are different.

5.3 The presence of a lubricant on the surfaces of the specimen and device may result in shear strengths up to 3 % lower than those determined in the absence of lubrication.

Note 3: In order to be able to test rivets having shanks as short as 2d, the supported lengths of the specimen are 1/2  d (Fig. 1), although it is recognized that higher values of shear strength would be obtained if the supporting lengths were longer.

 

d = nominal diameter of specimen (rivet, wire, or machined specimen),

 

d1 = actual diameter of hole (see Note), and

 

d2 = actual diameter of specimen

 

Clearance (d1 d2), maximum = 0.02 d + 0.005 in. (0.12 mm)

 

Note 1: The tolerance applicable to the diameter of the specimen being shear tested must be recognized in drilling the hole in the device. It is recommended that the drilled hole size be equal to 1.02 d plus 0.005 in. (0.12 mm) less the minus tolerance applicable to the specimen.

 

S1 = d

 

S2 = S1 + 0.001 in. (0.025 mm)

 

S3 = 1/4 in. (6 mm) for d = 1/16 in. (1.5 mm) to 5/32 in. (4 mm)

 

   = 1/2 in. (12 mm) for d = 3/16 in. (5 mm) to 3/8 in. (10 mm)

5.4 Investigations have determined that the shear strength decreases slightly as the clearance between the specimen diameter and the diameter of the test hole in the device increases, and that the effect of the clearance decreases with increasing specimen diameter. This test method (refer to Fig. 1) permits clearances for production testing which should affect shear strengths by no more than 2 %. For referee testing, the maximum clearance shall be 0.001 in. (0.03 mm).5

Keywords

double shear loading; shear test device; shear aluminum rivet ;

To find similar documents by ASTM Volume:

02.02 (Aluminum and Magnesium Alloys)

To find similar documents by classification:

77.150.30 (Copper products)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-B565-04(2015)

Revision Level

2004 R15 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Oct. 1, 2015

Document Type

Test Method

Page Count

3 pages

Committee Number

B07.05