ASTM-C1218 Historical Revision Information
Standard Test Method for Water-Soluble Chloride in Mortar and Concrete

ASTM-C1218 - 1999 R08 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Water-Soluble Chloride in Mortar and Concrete
ORDER

Scope

1.1 This test method provides procedures for the sampling and analysis of hydraulic-cement mortar or concrete for chloride that is water soluble under the conditions of test.

1.2 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes shall not be considered as requirements of this standard.

1.3 The values stated in either SI units or inch-pound units are to be regarded separately as a standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Water-soluble chloride, when present in sufficient amount, is capable of leading to initiation or acceleration of the corrosion of metals, such as steel, embedded in or contacting a cement system such as mortar, grout, or concrete. Thus, its determination shall be required to evaluate the potential of a cement system for undergoing such reactions or to investigate cement systems where such reaction has already occurred. However, it must be recognized that water-soluble chloride determined at some particular time in the life of a cement system is capable of being substantially different than that at another time; for example, the service environment is capable of resulting in a higher water-soluble chloride content due to changes in solubility or a lower one due to leaching.

Test conditions are capable of affecting water-soluble chloride determinations. Take caution when comparing results from this test method with those from other test methods.

Sulfides are known to interfere with the determination of chloride content. Blast-furnace slag aggregates and cements contain sulfide sulfur in concentrations that are capable of such interference and produce erroneously high test results. Treatment with hydrogen peroxide, as discussed in Test Methods C 114, is used to eliminate such interference.

There are aggregates that contain chloride that is not available for corrosion. Such chloride will be detected by use of this test method.

Keywords

chloride; chloride content; concrete; mortar; water-soluble chloride; Chloride analysis--concrete/aggregate; Concrete; Corrosion--concrete; Hydraulic cement mortar; Mortar; Water-soluble chloride

To find similar documents by ASTM Volume:

04.02 (Concrete and Aggregates)

To find similar documents by classification:

91.100.10 (Cement. Gypsum. Lime. Mortar)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-C1218/C1218M-99(2008)

Revision Level

1999 R08 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Jan. 1, 2008

Document Type

Test Method

Page Count

3 pages

Committee Number

C09.69