ASTM-C173 Historical Revision Information
Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method

ASTM-C173 - 2008A EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method
ORDER

Scope

1.1 This test method covers determination of the air content of freshly mixed concrete containing any type of aggregate, whether it be dense, cellular, or lightweight.

1.2 The values stated in either inch-pound or SI units shall be regarded separately as standard. The SI units are shown in brackets. The values stated are not exact equivalents; therefore each system must be used independently of the other. Combining values from the two units may result in nonconformance.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.(WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. )

Significance and Use

This test method covers the determination of the air content of freshly mixed concrete. It measures the air contained in the mortar fraction of the concrete, but is not affected by air that may be present inside porous aggregate particles.

Therefore, this is the appropriate test to determine the air content of concretes containing lightweight aggregates, air-cooled slag, and highly porous or vesicular natural aggregates.

This test method requires the addition of sufficient isopropyl alcohol, when the meter is initially being filled with water, so that after the first or subsequent rollings little or no foam collects in the neck of the top section of the meter. If more foam is present than that equivalent to 2 % air above the water level, the test is declared invalid and must be repeated using a larger quantity of alcohol. Addition of alcohol to dispel foam any time after the initial filling of the meter to the zero mark is not permitted.

The air content of hardened concrete may be either higher or lower than that determined by this test method. This depends upon the methods and amounts of consolidation effort applied to the concrete from which the hardened concrete specimen is taken; uniformity and stability of the air bubbles in the fresh and hardened concrete; accuracy of the microscopic examination, if used; time of comparison; environmental exposure; stage in the delivery, placement and consolidation processes at which the air content of the unhardened concrete is determined, that is, before or after the concrete goes through a pump; and other factors.

Keywords

air content; calibration; concrete; correction factor; freshly mixed concrete; measuring bowl; meter; volumetric method; Air content--concrete; Ready-mixed concrete--specifications; Volumetric measurement; ICS Number Code 91.100.30 (Concrete and concrete products)

To find similar documents by ASTM Volume:

04.02 (Concrete and Aggregates)

To find similar documents by classification:

91.100.30 (Concrete and concrete products Including admixtures)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-C173/C173M-08a

Revision Level

2008A EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Dec. 15, 2008

Document Type

Test Method

Page Count

8 pages

Committee Number

C09.60