Standard Specification for Asbestos-Cement Organic-Foam Core Insulating Panels
The following bibliographic material is provided to assist you with your purchasing decision:
This specification covers asbestos-cement organic-foam core insulating panels consisting of a core of insulating cellular plastic sandwiched between and bonded to two sheets of asbestos-cement facing board. Asbestos-cement plastic-foam core panels are normally nonload-bearing panels designed for exterior and interior walls, partitions, curtain walls, and other insulation and decorative purposes. Panels shall be sampled, tested, and conform accordingly to specified properties such as vapor permeability, thermal resistance, adhesive lime bond, flexural strength, breaking load strength, dimensions (thickness, width and length, and squareness), and workmanship, finish, and color.
Scope
1.1 This specification covers asbestos-cement plastic-foam core panels consisting of a core of insulating cellular plastic sandwiched between and bonded to two sheets of asbestos-cement facing board. Asbestos-cement plastic-foam core panels are normally nonload-bearing panels designed for exterior and interior walls, partitions, curtain walls, and other insulation and decorative purposes.
1.2 All measurements and tests necessary for determining the conformity of asbestos-cement plastic-foam core panels with this specification are made in accordance with the test methods covered in Sections 6 and 10.
1.3 The values stated in SI units are to be regarded as the standard. The values stated in parentheses are provided for information only.
1.4 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 1.4 for a specific hazard warning.
Keywords
Asbestos-cement--specifications; Core insulating panels; Dimensions--asbestos-cement products; Flexural testing--asbestos-cement products; Thermal insulating materials--specifications; Thermal insulating materials (asbestos-cement panels); ICS Number Code 91.100.40 (Products in fibre-reinforced cement)
To find similar documents by ASTM Volume:
To find similar documents by classification:
91.100.40 (Products in fibre-reinforced cement)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C659-90(2008)
Revision Level
1990 R08 EDITION
Status
Superseded
Modification Type
Reapproval
Publication Date
June 1, 2008
Document Type
Specification
Page Count
3 pages
Committee Number
C17.03