ASTM-D1005 Historical Revision Information
Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers

ASTM-D1005 - DOD VALIDATION 2 - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ORDER

Scope

1.1 This test method covers the measurement of film thickness of dried films of paint, varnish, lacquer, and related products using micrometers. Procedures A and B utilize stationary micrometers and Procedures C and D, hand-held micrometers. Procedures A and C are not recommended for films less than 0.5 mils (12.5 µm) in thickness. The minimum thickness required for Procedures B and D is a function of that required to enable removal of the sample as a free film.

1.2 The procedures appear as follows:

1.2.1 Procedure A--Stationary micrometer for measuring coatings applied to plane rigid surfaces.

1.2.2 Procedure B--Stationary micrometer for measuring free films.

1.2.3 Procedure C--Hand-held micrometer for measuring coatings applied to plane rigid surfaces.

1.2.4 Procedure D --Hand-held micrometer for measuring free films.

1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This test method is particularly applicable to the measurement of free films and is also satisfactory for the measurement of films on laboratory test panels.

The accuracy and precision of the thickness measurements may be influenced by the deformability of the coating. This test method is not applicable to coatings that are readily deformable under the load of the measuring instrument.

The accuracy and precision of the thickness measurements are also influenced by the uniformity of the substrate when the coatings are applied to laboratory test panels.

Keywords

dial comparator; dial indicator; dial indicator gage; film-dry film thickness; measurement of organic coatings; micrometer

To find similar documents by ASTM Volume:

06.01 (Paint -- Tests for Chemical, Physical, and Optical Properties; Appearance)

To find similar documents by classification:

25.220.60 (Organic coatings)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D1005

Revision Level

DOD VALIDATION 2

Status

Superseded

Modification Type

Reapproval

Publication Date

Feb. 19, 1991

Document Type

Test Method

Page Count

1 page

Committee Number

D01.23