ASTM-D1293 Historical Revision Information
Standard Test Methods for pH of Water

ASTM-D1293 - 2012 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Methods for pH of Water
ORDER

Scope

1.1 These test methods cover the determination of pH by electrometric measurement using the glass electrode as the sensor. Two test methods are given as follows:

Sections
Test Method APrecise Laboratory Measurement 8 to 15
Test Method BRoutine or Continuous Measurement 16 to 24

1.2 Test Method A covers the precise measurement of pH in water utilizing at least two of seven standard reference buffer solutions for instrument standardization.

1.3 Test Method B covers the routine measurement of pH in water and is especially useful for continuous monitoring. Two buffers are used to standardize the instrument under controlled parameters, but the conditions are somewhat less restrictive than those in Test Method A. For on-line measurement, also see Test Method D6569 which provides more detail.

1.4 Both test methods are based on the pH scale established by NIST (formerly NBS) Standard Reference Materials.

1.5 Neither test method is considered to be adequate for measurement of pH in water whose conductivity is less than about 5 μS/cm. Refer to Test Methods D5128 and D5464.

1.6 Precision and bias data were obtained using buffer solutions only. It is the user's responsibility to assure the validity of these test methods for untested types of water.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

The pH of water is a critical parameter affecting the solubility of trace minerals, the ability of the water to form scale or to cause metallic corrosion, and the suitability of the water to sustain living organisms. It is a defined scale, based on a system of buffer solutions with assigned values. In pure water at 25°C, pH 7.0 is the neutral point, but this varies with temperature and the ionic strength of the sample. Pure water in equilibrium with air has a pH of about 5.5, and most natural uncontaminated waters range between pH 6 and pH 9.

Keywords

hydrogen ion concentration; pH; pH buffer solution; Routine measurement (of pH) method; Water quality monitoring; Acidity, alkalinity, pH--water; Buffer solutions; Continuous measurement/monitoring; Field testing--water; Glass electrodes; Hydrogen ion concentration; Instrumental measurement--water; pH--glass electrode; pH--water; Precise laboratory measurement (of pH) method; Process pH measurements; Reference buffer solutions; Remote pH measurements; ICS Number Code 13.060.50 (Examination of water for chemical substances)

To find similar documents by ASTM Volume:

11.01 (Water (I))

To find similar documents by classification:

13.060.50 (Examination of water for chemical substances)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D1293-12

Revision Level

2012 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Jan. 31, 2012

Document Type

Test Method

Page Count

10 pages

Committee Number

D19.03