ASTM-D3941 Historical Revision Information
Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus

ASTM-D3941 - 1990 R07 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus
ORDER

Scope

1.1 This test method covers the determination of the flash point of liquids in which the specimen and the air/vapor mixture above it are approximately in temperature equilibrium.

1.2 This test method is limited to a temperature range from 0 to 110°C (32 to 230°F).

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard should be used to measure and describe the properties of material, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This test method, using a slow rate of heating, provides a uniform temperature throughout the specimen. The slow rate of heating is necessary because of the low thermal conductivity of some liquids such as paints, resins, and related products, and also because of the poor heat transfer by convection in high-viscosity products. Since the specimen is being heated at a reduced rate, the longer time interval between each determination is necessary to reestablish after each flash test the saturation concentration of vapor in the air space above the specimen.

Note 1—ISO 1523 is used in United Nations Recommendations for Transportation of Dangerous Goods and in the International Civil Aviation Organization (ICAO) regulations and for similar regulations in the International Maritime Dangerous Goods (IMDG) code. Test Method D 3941, which is similar to ISO 1523, is used in the United States Department of Transportation (USDOT) regulations. The ICAO and IMDG codes are used for transshipment of hazardous materials through the United States to other countries.

Keywords

closed cup; equilibrium method; flash point; Pensky-Martens; Tag; ICS Number Code 87.040 (Paints and varnishes)

To find similar documents by ASTM Volume:

06.01 (Paint -- Tests for Chemical, Physical, and Optical Properties; Appearance)

To find similar documents by classification:

87.040 (Paints and varnishes Including coating powders, paint coatings and protective paint systems)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D3941-90(2007)

Revision Level

1990 R07 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

June 1, 2007

Document Type

Test Method

Page Count

3 pages

Committee Number

D01.21