ASTM-D5032 › Historical Revision Information
Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This practice describes a method for obtaining constant relative humidity ranging from 30 to 98 % at temperatures ranging from 0 to 70°C in relatively small containers by means of an aqueous glycerin solution.
1.2 This practice is applicable for closed systems such as environmental conditioning containers.
1.3 This practice is not recommended for the generation of continuous (flowing) streams of constant humidity unless precautionary criteria are followed to ensure source stability.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use
Controlled relative humidity environments are important for conditioning materials for shelf-life studies or for investigating the change in physical or dielectric properties after exposure.
The use of aqueous-glycerin solutions reduces the possibility of contamination of the materials or corrosion of electrode systems which would be more likely to result from saturated salt or acid water solutions.
Applicable material specifications should state the exposure conditions, including time, temperature and relative humidity that a material should be subjected to before subsequent testing. Typical conditions are given in Practice D618 or D6054.
Keywords
aqueous glycerin solutions; conditioning; constant relative humidity; glycerin; relative humidity: Aqueous solutions; Atmospheres--conditioning/testing; Conditioning--electrical insulating materials; Constant relafive humidity; Contamination prevention; Controlled testing conditions/environments; Dielectric breakdown voltage; Dielectric properties/testing; Glycerin; Permittivity (dielectric constant); Relative humidity (RH); Temperature tests--room; ICS Number Code 07.060 (Geology. Meteorology. Hydrology); 91.140.30 (Ventilation and air-conditioning systems)
To find similar documents by ASTM Volume:
10.02 (Electrical Insulation (II): D2518 - latest)
To find similar documents by classification:
07.060 (Geology. Meteorology. Hydrology)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D5032-11
Revision Level
2011 EDITION
Status
Superseded
Modification Type
Revision
Publication Date
Sept. 15, 2011
Document Type
Practice
Page Count
3 pages
Committee Number
D09.12