ASTM-D5921 Historical Revision Information
Standard Practice for Subsurface Site Characterization of Test Pits for On-Site Septic Systems

ASTM-D5921 - 1996(E1) EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Subsurface Site Characterization of Test Pits for On-Site Septic Systems (Withdrawn 2019)
ORDER

Scope

1.1 This practice covers procedures for the characterization of subsurface soil conditions at a site as part of the process for evaluating suitability for an on-site septic system. This practice provides a method for determining the usable unsaturated soil depth for septic tank effluent to infiltrate for treatment and disposal.

1.2 This practice describes a procedure for classifying soil by field observable characteristics within the United States Department of Agriculture, Soil Conservation Service (SCS) classification system. The SCS classification system is defined in Refs (1-4), not in this practice. This practice is based on visual examination and manual tests that can be performed in the field. This practice is intended to provide information about soil characteristics in terms that are in common use by soil scientists, public health sanitarians, geologists, and engineers currently involved in the evaluation of soil conditions for septic systems.

1.3 This procedure can be augmented by Test Method D 422, when verification or comparison of field techniques is required. Other standard test methods that may be used to augment this practice include: Test Methods D 2325, D 3152, D 5093, D 3385, and D 2434.

1.4 This practice is not intended to replace Practice D 2488 which can be used in conjunction with this practice if construction engineering interpretations of soil properties are required.

1.5 This practice should be used in conjunction with D 5879 to determine a recommended field area for an on-site septic system. Where applicable regulations define loading rates-based soil characteristics, this practice, in conjunction with D 5925, can be used to determine septic tank effluent application rates to the soil.

1.6 This practice should be used to complement standard practices developed at state and local levels to characterize soil for on-site septic systems.

1.7 The values stated in SI units are to be regarded as the standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

septic system; site characterization; soil classification; soil description; visual classification; ICS Number Code 13.060.30 (Sewage water)

To find similar documents by ASTM Volume:

04.09 (Soil and Rock (II): D5877 - latest)

To find similar documents by classification:

13.060.30 (Sewage water Including sewage water disposal and treatment Liquid wastes, see 13.030.20 Drainage systems, see 91.140.80 Sewage systems, see 93.030)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D5921-96e1

Revision Level

1996(E1) EDITION

Status

Superseded

Modification Type

Editorially changed

Publication Date

Oct. 1, 1998

Document Type

Practice

Page Count

16 pages

Committee Number

D18.01