ASTM-D6023 › Historical Revision Information
Standard Test Method for Unit Weight, Yield, Cement Content, and Air Content (Gravimetric) of Controlled Low Strength Material (CLSM)
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method explains determination of the mass per cubic foot (cubic meter) of freshly mixed Controlled Low Strength Material (CLSM) and gives formulas for calculating the yield, cement content, and the air content of the CLSM. This test method is based on Test Method C 138 for Concrete.
Note 1—Unit Weight is the traditional terminology used to describe the property determined by this test method. The proper term is density. It has also been termed unit mass or bulk density. To be compatible with terminology used in the concrete industry, unit weight is referenced in this test method.
1.2 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026.
1.2.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.
1.3 The values stated in SI units are to be regarded as standard. The inch-pound equivalents are shown for information only.
1.4 CLSM is also known as flowable fill, controlled density fill, soil-cement slurry, soil-cement grout, unshrinkable fill, "K-Krete," and other similar names.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use
This test method provides the user with a procedure to calculate the density of freshly mixed CLSM for determination of compliance with specifications, for determining mass/volume relationships or conversions such as those found in purchase agreements, and also for quality control purposes.
This test method is intended to assist the user for quality control purposes and when specified to determine compliance for air content, yield, and cement content of freshly mixed CLSM.
This test method is not meant to predict the air content of hardened CLSM, which may be either higher or lower than that determined by this test method.
This test is one of a series of quality control tests that can be performed on CLSM during construction to monitor compliance with specification requirements. The other tests that can be used during construction control are Test Methods D 4832
Note 2—The qulaity of the results produced by this standard is dependent on the competence of the personnel performing it and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D 3740
Keywords
air content; backfill; cement content; CLSM; construction control; density; flowable fill; mix design; quality control; relative yield; soil stabilization; unit weight; yield; ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
To find similar documents by ASTM Volume:
04.09 (Soil and Rock (II): D5877 - latest)
To find similar documents by classification:
91.100.10 (Cement. Gypsum. Lime. Mortar)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D6023-02
Revision Level
2002 EDITION
Status
Superseded
Modification Type
Adopt as a Standard with Revision
Publication Date
July 10, 2002
Document Type
Test Method
Page Count
4 pages
Committee Number
D18.15