ASTM-D6764 Historical Revision Information
Standard Guide for Collection of Water Temperature, Dissolved-Oxygen Concentrations, Specific Electrical Conductance, and pH Data from Open Channels

ASTM-D6764 - 2002 R13 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Collection of Water Temperature, Dissolved-Oxygen Concentrations, Specific Electrical Conductance, and pH Data from Open Channels
ORDER

Scope

1.1 This guide describes procedures to collect cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of water flowing in open channels.

1.2 This guide provides guidelines for preparation and calibration of the equipment to collect cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of water flowing in open channels.

1.3 This guide describes what equipment should be used to collect cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of water flowing in open channels.

1.4 This guide covers the cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of fresh water flowing in open channels.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Significance and Use

5.1 This guide describes stabilization criteria for recording field measurements of Temperature, DO, SC, and pH.

5.2 This guide describes the procedures used to calibrate and check meters to be used in the field to records these measurements and the procedures to be use in the field to obtain these data.

5.3 This guide describes quality assurance procedures to be followed when obtaining cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of water flowing in open channels.

TABLE 1 Stabilization Criteria for Recording Field Measurements (1)
Note 1[±, plus or minus value shown; °C, degrees Celsius; less than or equal to values shown; μS/cm microsiemens at 25°C, >, greater than value shown; unit, standard pH unit; mg/L milligram per liter].

Standard Direct
Field Measurement

Stabilization Criteria for Measurements
(Variability Should Be Within the Value Shown)

Temperature:
 Electronic Temperature Sensor
 Liquid-in-glass thermometer


±0.2°C
±0.5°C

Specific Electrical Conductance:
 when 100 mS/cm
 when > 100 mS/cm


±5 %
±5 %

pH:
 Meter displays to 0.01


±0.1 unit

Dissolved oxygen:
 Amperometric method


±0.3 mg/L


5.4 Field measurement must accurately represent the water flowing in the open channel being measured. Methods need to be used that will result in an accurate representation of the mean of the parameter of interest. Procedures must be used that will take into consideration the variation in the parameter across the sections and with depth.

5.5 Temperature and DO must be measured directly in the water in the open channel. SC and pH are often measured in situ, but also may be measured in a subsample of a composite sample collected using discharge-weighted methods.

Keywords

dissolved oxygen; pH; sampling; specific conductance; surface-water; temperature

To find similar documents by ASTM Volume:

11.01 (Water (I))

To find similar documents by classification:

13.060.50 (Examination of water for chemical substances)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D6764-02(2013)

Revision Level

2002 R13 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Feb. 1, 2013

Document Type

Guide

Page Count

16 pages

Committee Number

D19.07