ASTM-E1164 Historical Revision Information
Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation

ASTM-E1164 - 2009A EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation
ORDER

Scope

1.1 This practice covers the instrumental measurement requirements, calibration procedures, and material standards needed to obtain precise spectral data for computing the colors of objects.

1.2 This practice lists the parameters that must be specified when spectrometric measurements are required in specific methods, practices, or specifications.

1.3 Most sections of this practice apply to both spectrometers, which can produce spectral data as output, and spectrocolorimeters, which are similar in principle but can produce only colorimetric data as output. Exceptions to this applicability are noted.

1.4 This practice is limited in scope to spectrometers and spectrometric colorimeters that employ only a single monochromator. This practice is general as to the materials to be characterized for color.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

The most general and reliable methods for obtaining CIE tristimulus values or, through transformation of them, other coordinates for describing the colors of objects are by the use of spectrometric data. Colorimetric data are obtained by combining object spectral data with data representing a CIE standard observer and a CIE standard illuminant, as described in Practice E 308.

This practice provides procedures for selecting the operating parameters of spectrometers used for providing data of the desired precision. It also provides for instrument calibration by means of material standards, and for selection of suitable specimens for obtaining precision in the measurements.

Keywords

color; instrumental measurementcolor; lighttransmission and reflection; reflectance and reflectivity; spectrometry; transmittance and reflectance; Calibration--paints/related coatings analysis instrumentation; CIE color-scale system; CIE tristimulus values; Color; Data analysis--paints/related coatings; Diffuse reflectance; Dispersion; Illumination; Incandescent lamps; Instrumental measurement--color/light; Luminous reflectance factor; Normal/total/diffuse reflectance/transmittance; Object-color specimens; Parameters; Reciprocal measurement; Reflectance and reflectivity--paints/related coatings/materials; Specimen preparation (for testing)--paints/related coatings; Spectrocolorimeter; Spectrophotometry; Spectrophotometry--absorption; Total/normal reflectance/transmittance; Transmittance and reflectance; Tristimulus value; Viewing geometries; Wavelength accuracy; Xenon-arc light exposure; ICS Number Code 17.180.20 (Colours and measurement of light)

To find similar documents by ASTM Volume:

06.01 (Paint -- Tests for Chemical, Physical, and Optical Properties; Appearance)

To find similar documents by classification:

17.180.20 (Colours and measurement of light)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1164-09a

Revision Level

2009A EDITION

Status

Superseded

Modification Type

Revision

Publication Date

June 1, 2009

Document Type

Practice

Page Count

8 pages

Committee Number

E12.02