ASTM-E1536 Historical Revision Information
Standard Practice for Detection of Mycoplasma Contamination of Bovine Serum by Large Volume Method (Withdrawn 2014)

ASTM-E1536 - 2000 R06 EDITION - CANCELLED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Detection of Mycoplasma Contamination of Bovine Serum by Large Volume Method (Withdrawn 2014)
ORDER

Scope

1.1 This practice covers the procedures used for detection of mycoplasma contamination in serum by direct microbiological culture.

1.2 This practice does not cover procedures used for detection of mycoplasma in cell cultures.

1.3 This practice does not cover indirect methods for detection of mycoplasma contamination.

1.4 This practice does not cover methods for identification of mycoplasma cultures.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Mycoplasmas of bovine origin are prevalent contaminants of cell cultures. Contamination can be detected by the large volume method.3 ,4

Heat inactivated serum need not be tested for mycoplasmas. Heating serum to 56°C for 30 min will kill mycoplasmas.

Mycoplasmas may be present in any particular lot of serum but may not be detected because of inadequate sample size; thus, negative test results do not provide absolute assurance that the test serum is free of mycoplasmas.

Keywords

mycoplasma; serum; ICS Number Code 07.100.10 (Medical microbiology)

To find similar documents by ASTM Volume:

11.06 (Biological Effects and Environmental Fate; Biotechnology)

14.02 (General Test Methods; Forensic Psychophysiology; Forensic Sciences; Terminology; Conformity Assessment; Statistical Methods; Nanotechnology; Forensic Engineering; Manufacture of Pharmaceutical Products)

To find similar documents by classification:

07.100.10 (Medical microbiology Laboratory medicine, see 11.100)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1536-00(2006)

Revision Level

2000 R06 EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

Jan. 1, 2006

Document Type

Practice

Page Count

2 pages

Committee Number

E55.04