ASTM-E1637 Historical Revision Information
Standard Specification for Structural Standing Seam Aluminum Roof Panel Systems

ASTM-E1637 - 1998 R03 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification covers the design, construction, and weatherability of structural standing seam aluminum roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers. Structural panels shall be designed in accordance with the required specifications for aluminum structures and in accordance with sound engineering methods and practices. The static load capacity and uplift index shall be tested to meet the requirements prescribed. Connections of panels to structural members shall be made with concealed panel clips compatible with the panel design. A fixing line is required to anchor roof panels in order to maintain end alignment and to resist in-plane gravity and thermal force components. Panel-to-panel sidelap connections and endlaps shall be weathertight. Panels of maximum practicable lengths shall be used to minimize endlaps.

ORDER

Scope

1.1 This specification covers the design, construction, and weatherability of structural standing seam aluminum roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers.

Note 1—These systems are used on both low-slope and steep-slope roof applications. They also are used with or without an underlying deck or sheathing.

1.2 The objective of this specification is to provide for the overall performance of the structural standing seam aluminum roof panel system as defined in during its service life in order to provide weather protection, carry the specified design loads, and allow proper access over the roof surface in order to provide for periodic maintenance of the equipment by the building owner.

1.3 In addition to structural characteristics, the specifier shall evaluate other characteristics beyond the scope of this specification that affect the final choice of roof construction. These include, but are not limited to, functional, legal, insurance, and economic considerations. See for the specifier's checklist.

1.4 This specification is not intended to exclude products or systems not covered by the referenced documents.

1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 The text of this specification contains notes and footnotes that provide explanatory information and are not requirements of this specification.

Keywords

aluminum; anchorage; clips; construction; deflection; endlaps; environmental; exposed; exposures; fasteners; flashings; installation; joints; loading; loads; low-sloped; metal; oil canning; panels; penetrations; ponding; roof; sealer; seismic; service life; sidelap; slope; snow; standing seam; structural; superimposed; tapes; thermal; uplift; water; weathertightness

To find similar documents by ASTM Volume:

04.11 (Building Constructions (I): E72 - E2110)

To find similar documents by classification:

77.150.10 (Aluminium products)

91.060.20 (Roofs Including related elements (gutters, etc.))

91.100.99 (Other construction materials)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1637-98(2003)

Revision Level

1998 R03 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Oct. 10, 2003

Document Type

Specification

Page Count

5 pages

Committee Number

E06.57