ASTM-E1768 Historical Revision Information
Standard Guide for Ventilatory Behavioral Toxicology Testing of Freshwater Fish

ASTM-E1768 - 1995 R03(E1) EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Ventilatory Behavioral Toxicology Testing of Freshwater Fish (Withdrawn 2022)
ORDER

Scope

1.1 This guide covers information on methods to measure and interpret ventilatory behavioral responses of freshwater fish to contaminants.

1.2 Ventilatory responses are often some of the first prelethal symptoms exhibited by animals to environmental stressors (1, 2, 3, 4, 5, 6, 7, 8, 9, 10). Continued, abnormal ventilatory behavior (that is, rapid or shallow breathing, erratic breathing) can indicate physiological damage that may be irreversible. Such damage could eventually result in decreased survival, growth, or reproduction of the organism, or all of these.

1.3 Ventilatory responses of some fish species can be measured relatively easily and quickly, providing a useful tool for biomonitoring studies of wastewaters, pure chemicals, surface water, and ground water.

1.4 Appropriate studies of ventilatory responses can yield definitive endpoints such as no observable effect concentration (NOEC) or an EC50, often more rapidly than standard toxicity test methods (11, 12).

1.5 The mode of action of test substances and the type of chemical toxicant can be determined by examining ventilatory behavioral responses in conjunction with other physiological responses (8, 9, 10, 11, 12).

1.6 Fish ventilatory behavior can be assessed in real-time using appropriate computer hardware and software (12, 13, 14, 15, 16, 17, 18, 19). Such systems have proved useful for long-term, on-line monitoring of wastewater effluents, pure chemicals, and surface waters (12, 15, 20, 21, 23, 24, 25). These systems are usually technically complex and will not be discussed in this guide.

1.7 Given the technological constraints of electrical components, it is currently not feasible to monitor bioelectric signals, such as those elicited in ventilatory behavior, in saline (>2 ppt) or high conductivity (>3000 μmhos/cm) water using the procedures discussed in this guide. Therefore, this guide is restricted to the testing of freshwater matrices.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety precautions, see Section 6.

1.9 This guide is arranged as follows:

Section Number
Scope1
Referenced Documents2
Terminology3
Summary of Guide4
Significance and Use5
Safety Precautions6
Responses Measured7
Test System8
Test Procedure9
Data Collection and Analysis10
Interferences11
Documentation12
References13

Keywords

measure; ventilatory; endpoints; electrical; ICS Number Code 11.100 (Laboratory medicine); 11.220 (Veterinary medicine)

To find similar documents by ASTM Volume:

11.05 (Pesticides and Alternative Control Agents; Environmental Assessment; Hazardous Substances and Oil Spill Response)

11.06 (Biological Effects and Environmental Fate; Biotechnology)

To find similar documents by classification:

11.100 (Laboratory medicine)

11.220 (Veterinary medicine Including equipment specific to veterinary medicine)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1768-95(2003)e1

Revision Level

1995 R03(E1) EDITION

Status

Superseded

Modification Type

Reapproval with Ed Change

Publication Date

Aug. 10, 2003

Document Type

Guide

Page Count

10 pages

Committee Number

E47.01