ASTM-E1924 Historical Revision Information
Standard Guide for Conducting Toxicity Tests with Bioluminescent Dinoflagellates

ASTM-E1924 - 1997 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Conducting Toxicity Tests with Bioluminescent Dinoflagellates (Withdrawn 2013)
ORDER

Scope

1.1 This guide covers two distinct procedures, based on similar principles, for obtaining data concerning the adverse effects of a test material (added to dilution water) on oceanic bioluminescent dinoflagellates.

1.1.1 The endpoint for both procedures is based on a measurable reduction or inhibition in light output from the dinoflagellates. Both procedures are similar in that when bioluminescent dinoflagellates are exposed to toxicants, a measurable reduction in bioluminescence is observed from their cells following mechanical stimulation when compared to control cells. In the first procedure, cells of the bioluminescent dinoflagellate Gonyaulax polyedra can be tested over a range of up to seven days of exposure (or longer) to a toxicant. The second procedure uses another species, Pyrocystis lunula, for a 4 h test.

1.2 Both procedures can measure the toxic effects of many chemicals, various marine and freshwater effluents, antifouling coatings, leachates, and sediments to bioluminescent dinoflagellates (1-5). Compounds with low water solubility such as large organic molecules may be solubilized with methanol, ethanol, and acetone solvents for testing (4) (see Guide E 729).

1.3 An IC50 in light output (bioluminescence) is the recommended endpoint (1). However, percent inhibition of bioluminescence is an appropriate endpoint in some cases (5).

1.4 Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting acute and chronic tests.

1.5 The values stated in SI units are to be regarded as the standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

bioluminescence; dark phase; dinoflagellate; Gonyaulax Ployedra; inhibition; light output; Pyrocystis lanula; toxicity test; ICS Number Code 11.120.01 (Pharmaceutics in general)

To find similar documents by ASTM Volume:

11.05 (Pesticides and Alternative Control Agents; Environmental Assessment; Hazardous Substances and Oil Spill Response)

11.06 (Biological Effects and Environmental Fate; Biotechnology)

To find similar documents by classification:

11.100.99 (Other standards related to laboratory medicine)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1924-97

Revision Level

1997 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Dec. 10, 1997

Document Type

Guide

Page Count

11 pages

Committee Number

E47.01