ASTM-E2197 Historical Revision Information
Determining the Bactericidal, Virucidal, Fungicidal, Microbactericidal & Sporicidal Activi

ASTM-E2197 - 2002 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Quantitative Disk Carrier Test Method for Determining Bactericidal, Virucidal, Fungicidal, Mycobactericidal, and Sporicidal Activities of Chemicals
ORDER

Scope

1.1 The method is designed to evaluate the ability of liquid chemical germicides to inactivate vegetative bacteria, viruses, fungi, mycobacteria and bacterial spores in the presence of a soil load (1,2) on disk carriers that represent environmental surfaces and medical devices. It is also designed to have survivors that can be compared to mean of no less than three control carriers to determine if the performance standard has been met. For proper statistical evaluation of the results, the size of the test inoculum should be sufficiently large to take into account both the performance standard and the experimental variation in the results.

1.2 The test protocol does not include any wiping or rubbing action. It is, therefore, not designed for testing germicide-soaked wipes.

1.3 This test method should be performed by persons with training in microbiology in facilities designed and equipped for work with infectious agents at the appropriate biosafety level ().

1.4 In this test method, metric units are used for all applications, except for distance in which case inches are used and metric units follow.

1.5 It is the responsibility of the investigator to determine whether Good Laboratory Practice Regulations (GLPs) are required and to follow them where appropriate (40 CFR, Part 160 for EPA submissions and 21 CFR, Part 58 for FDA submissions).

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Adenovirus; Bacillus subtilis spores; bactericides; cell cultures; chemical germicides; Clostridium sporogenes spores; eluate; eluent; environmental surfaces; fungicides; hepatitis A virus; medical devices; membrane filtration; mycobactericides; Mycobacterium terrae; Pseudomonas aeruginosa; quantitative carrier test; rhinovirus; rotavirus; soil load; sporicides; Staphylococcus aureus; standard hard water; surrogate; Trichophyton mentagrophytes conidia; virucides; viruses; ICS Number Code 07.100.01 (Microbiology in general)

To find similar documents by ASTM Volume:

11.05 (Pesticides and Alternative Control Agents; Environmental Assessment; Hazardous Substances and Oil Spill Response)

To find similar documents by classification:

07.100.01 (Microbiology in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E2197-02

Revision Level

2002 EDITION

Status

Superseded

Modification Type

New

Publication Date

April 10, 2002

Document Type

Test Method

Page Count

10 pages

Committee Number

E35.15