ASTM-F2565 Historical Revision Information
Standard Guide for Extensively Irradiation-Crosslinked Ultra-High Molecular Weight Polyethylene Fabricated Forms for Surgical Implant Applications

ASTM-F2565 - 2006 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This guide covers extensively irradiation-crosslinked ultra-high molecular weight polyethylene (UHMWPE) fabricated forms for surgical implant applications. Only gamma and electron beam irradiated extensively crosslinked materials are covered by this guide. Chemical composition and physical properties of extensively crosslinked UHMWPE fabricated form shall conform to the requirements of this guide which include ultimate tensile strength, yield strength, elongation, Izod impact strength, ultimate load, fatigue crack propagation, compressive modulus, percent crystallinity, melting temperature, residual free radicals, swell ratio, oxidation index, and t-vinylene content. Biocompatibility of the material shall also be considered when new applications of the material, or modification to the material or physical forms of the materials are being contemplated.

ORDER

Scope

1.1 This guide covers extensively crosslinked ultra-high molecular weight polyethylene (UHMWPE) materials (fabricated forms) that are produced starting with virgin resin powders and consolidated forms meeting all the requirements of Test Method F 648.

1.2 This guide does not cover fabricated forms of ultra-high molecular weight polyethylene which have received only gas plasma, ethylene oxide, or less than 40 kGy ionizing radiation treatments, that is, materials treated only by historical sterilization methods.

1.3 This guide pertains only to UHMWPE materials extensively crosslinked by gamma and electron beam sources of ionizing radiation.

1.4 The specific relationships between these mechanical properties and the in vivo performance of a fabricated form have not been determined. While trends are apparent, specific property-polymer structure and polymer-design relationships are not well understood. These mechanical tests are frequently used to evaluate the reproducibility of a fabrication procedure and are applicable for comparative studies of different materials.

1.5 The following precautionary caveat pertains only to the test method portion, Section 5, of this guide. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

fabricated forms; powdered form; ultra-high molecular weight polyethylene; ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics); 83.080.10 (Thermosetting materials)

To find similar documents by ASTM Volume:

13.02 (Emergency Medical Services; Search and Rescue; Anesthetic and Respiratory Equipment)

To find similar documents by classification:

11.040.40 (Implants for surgery, prosthetics and orthotics Including pacemakers Ophthalmic implants, see 11.040.70)

83.080.10 (Thermosetting materials Including ebonite Silicones, see 71.100.55)

This document comes with our free Notification Service, good for the life of the document.