ASTM-F2677 Standard Specification for Electrically Insulating Aprons

ASTM-F2677 - 2008A R24 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification prescribes the function and performance criteria, and acceptance testing for electrically insulating aprons for the protection of workers from incidental contact with live electrical apparatus or circuits. Three types of aprons are provided and are designated as follows: Type I, made from properly vulcanized high-grade cis-1,4-polyisoprene rubber compound of natural or synthetic origin that are non-resistant to ozone; Type II, made of any elastomer or combination of elastomeric compounds that are resistant to ozone; and Type III, made of any combination of elastomer and thermoplastic polymers that are elastic in nature and resistant to ozone. Six classes of insulating aprons, designated as Class 00, 0, 1, 2, 3, and 4, are assigned according to electrical characteristics. Aprons shall be tested for their conformance with specified chemical, physical, and electrical requirements.

ORDER

Price:

$55.00        


Want this as a site license?

Scope

1.1 This specification covers the acceptance testing of electrically insulating aprons for the protection of workers from incidental contact with live electrical apparatus or circuits.

1.2 The objective of this specification is to prescribe function and performance criteria for insulating aprons that meet a minimum level of electrically insulating and physical performance characteristics.

1.3 Three types of aprons are provided and are designated as Type I, non-resistant to ozone, Type II and Type III, resistant to ozone.

1.4 Six classes of insulating aprons, differing in electrical characteristics, are provided and are designated as Class 00, Class 0, Class 1, Class 2, Class 3, and Class 4.

Keywords

electrically insulating apron; lineman; lineman protective equipment; ICS Number Code 13.260 (Protection against electric shock. Live working)

To find similar documents by ASTM Volume:

10.03 (Electrical Insulating Liquids and Gases; Electrical Protective Equipment)

To find similar documents by classification:

13.260 (Protection against electric shock. Live working Including tools for working with voltages)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

ASHRAE-55
Thermal Environmental Conditions for Human Occupancy (ANSI approved)

ASHRAE-62.2
Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

ASHRAE-62.1
Ventilation for Acceptable Indoor Air Quality

Document Number

ASTM-F2677-08AR24

Revision Level

2008A R24 EDITION

Status

Current

Modification Type

New

Publication Date

Feb. 7, 2024

Document Type

Specification

Committee Number

F18.15