This document specifies a continuous measurement method for the determination of the concentration of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance. The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air from 0 µg/m3 to 500 µg/m3. This concentration range represents the certification range for NO2 for the type approval test. NOTE 1 0 µg/m3 to 500 µg/m3 of NO2 corresponds to 0 nmol/mol to 261 nmol/mol of NO2. The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air from 0 µg/m3 to 1 200 µg/m3. This concentration range represents the certification range for NO for the type approval test. NOTE 2 0 µg/m3 to 1 200 µg/m3 of NO corresponds to 0 nmol/mol to 962 nmol/mol of NO. The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations. NOTE 3 Lower ranges may be used for measurement systems applied at rural locations monitoring Ecosystems. The results are expressed in µg/m3 (at 293 K and 101,3 kPa). When the standard is used for other purposes than the EU Directive, the range and uncertainty requirements need not apply.

To find similar documents by classification:

13.040.20 (Ambient atmospheres Including indoor air)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

ORDER



Designation Name

SS-EN 14211:2005

Revision Level

2005 EDITION

Status

Superseded

Publication Date

March 24, 2005

Language(s)

English

Page Count

93

International Equivalent

EN 14211:2005(IDT)