SS-EN-ISO-22442-1 Historical Revision Information
Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management (ISO 22442-1:2015)

SS-EN-ISO-22442-1 - 2015 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This part of ISO 22442 applies to medical devices other than in vitro diagnostic medical devices manufactured utilizing materials of animal origin, which are non-viable or have been rendered non-viable. It specifies, in conjunction with ISO 14971, a procedure to identify the hazards and hazardous situations associated with such devices, to estimate and evaluate the resulting risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, it outlines the decision process for the residual risk acceptability, taking into account the balance of residual risk, as defined in ISO 14971, and expected medical benefit as compared to available alternatives. This part of ISO 22442 is intended to provide requirements and guidance on risk management related to the hazards typical of medical devices manufactured utilizing animal tissues or derivatives such asa) contamination by bacteria, moulds or yeasts;b) contamination by viruses;c) contamination by agents causing Transmissible Spongiform Encephalopathies (TSE);d) material responsible for undesired pyrogenic, immunological or toxicological reactions.For parasites and other unclassified pathogenic entities, similar principles can apply.This part of ISO 22442 does not stipulate levels of acceptability which, because they are determined by a multiplicity of factors, cannot be set down in such an International Standard except for some particular derivatives mentioned in Annex C. Annex C stipulates levels of TSE risk acceptability for tallow derivatives, animal charcoal, milk and milk derivatives, wool derivatives and amino acids.This part of ISO 22442 does not specify a quality management system for the control of all stages of production of medical devices.This part of ISO 22442 does not cover the utilization of human tissues in medical devices.

To find similar documents by classification:

11.100.20 (Biological evaluation of medical devices Medical microbiology, see 07.100.10)

11.100.99 (Other standards related to laboratory medicine)


Medical devices

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

ORDER



Designation Name

SS-EN ISO 22442-1:2015

Revision Level

2015 EDITION

Status

Superseded

Publication Date

Dec. 1, 2015

Language(s)

English

Page Count

44

International Equivalent

EN ISO 22442-1:2015(IDT); ISO 22442-1:2015(IDT)