ASTM-C1127 › Historical Revision Information
Standard Guide for Use of High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane with an Integral Wearing Surface
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This guide describes the design and installation of cold liquid-applied elastomeric waterproofing membrane systems that have an integral wearing surface. The cold liquid-applied elastomeric waterproofing membrane (membrane) to which this guide refers is specified in Specification C 957
1.2 Concrete Slab-on-Grade—Waterproofing the upper surface of a concrete slab on grade presents special problems due to the possibility of negative hydrostatic pressure causing loss of bond to the substrate. Consideration of these problems is beyond the scope of this guide. Consult the membrane manufacturer for recommendations when this situation exists.
1.3 The committee having jurisdiction for this guide is not aware of any similar ISO standard.
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Note in 15.4.
Significance and Use
This guide is divided into two sections which provide design and specification guidelines for the use of a cold liquid-applied elastomeric membrane with integral wearing surface for waterproofing building decks in building areas to be occupied by personnel, vehicles, or equipment.
The intent of Sections 5-11, Design Considerations, is to provide information and design guidelines where a waterproofing membrane with integral wearing surface is to be used. The intent of the remaining sections is to provide minimum guide specifications for the use of the purchaser and the seller in contract documents.
Where the state of the art is such that criteria for a particular condition is not as yet firmly established or has numerous variables that require consideration, reference is made to the applicable portion of Sections 5-11 that covers the particular area of concern. Section 16 describes the repair, rehabilitation, and replacement of the membrane.
DESIGN CONSIDERATIONS
Keywords
design; installation; membrane; waterproofing; Substrates; Surface preparation; Building design and construction; Decks; Elastomeric seals/sealants; Elastomeric waterproofing membranes; Installation--building materials/applications; Integral wearing surfaces; Plazas; Plywood; Roofing membranes; Solid phase materials; Structural concrete; Structural roof decks; ICS Number Code 83.140.99 (Other rubber and plastic products)
To find similar documents by ASTM Volume:
04.04 (Roofing and Waterproofing)
To find similar documents by classification:
83.140.99 (Other rubber and plastics products)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C1127-01(2009)
Revision Level
2001 R09 EDITION
Status
Superseded
Modification Type
Reapproval
Publication Date
Jan. 1, 2009
Document Type
Guide
Page Count
13 pages
Committee Number
D08.25