ASTM-C177 Historical Revision Information
Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus

ASTM-C177 - 1997 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
ORDER

Scope

1.1 This test method covers the achievement and measurement of steady-state heat flux through flat-slab specimens using a guarded-hot-plate apparatus. The method encompasses both the single-sided and the double-sided mode of measurement. Both distributed and line source guarded heating plate designs are included, in principle, in this test method. The reader should consult the standard practices on the single-sided mode of operation and on the line source apparatus for further details on these variations of the method.

1.2 The calculations of thermal transmission properties based upon measurements using this method shall be performed in conformance with Practice C1045.

1.3 This is an absolute (or primary) method of measurement since no heat flux reference standards are required except to confirm accuracy statements and to establish traceability to recognized standards. This absolute method is contrasted with a comparative (or secondary) method, such as Test Method C518, in which the results are directly dependent on heat flux reference standards.

1.4 This test method is applicable to the measurement of a wide variety of specimens, ranging from opaque solids to porous or transparent materials, and a wide range of environmental conditions. Special precautions in the measurement process are described for the following:

1.4.1 Specimens exhibiting appreciable inhomogeneities, anisotropies, rigidity, or extremes of thermal flux density.

1.4.2 Measurements conducted at extremes of temperature (either high or low) or under vacuum conditions.

1.5 This test method is intended to allow a wide variety of apparatus designs and design accuracies to satisfy the requirements of specific measurement problems. Compliance with this test method requires a statement of the uncertainty of each reported variable in the report. Therefore, in the following sections, the significant error factors will be discussed.

1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Heat flux; Hot plate/box methods; Insulating specimens; R-value; Surface analysis; Temperature tests-plast; Temperature tests-thermal insulation; Thermal transmission properties-steady-state; steady-state heat flux/thermal transmission properties of insulating; specimens, by guarded-hot-plate apparatus, test; ICS Number Code 17.200.10 (Heat. Calorimetry)

To find similar documents by ASTM Volume:

04.06 (Thermal Insulation; Building and Environmental Acoustics)

To find similar documents by classification:

17.200.10 (Heat. Calorimetry)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-C177-97

Revision Level

1997 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Feb. 10, 1997

Document Type

Test Method

Page Count

22 pages

Committee Number

C16.30