ASTM-D3687 Historical Revision Information
Standard Practice for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method

ASTM-D3687 - 2007 R12 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method
ORDER

Scope

1.1 This practice covers the applications of methods for the extraction and gas chromatographic determination of organic vapors that have been adsorbed from air in sampling tubes packed with activated charcoal.

1.2 This practice is complementary to Practice D3686.

1.3 This practice is applicable for analysis of samples taken from workplace or other atmospheres provided that the contaminant adsorbs onto charcoal, that it can be adequately extracted from the charcoal, and that it can be analyzed by gas chromatography (GC). Other adsorbents and other extraction techniques are described in Practice D6196.

1.4 Organic compounds of multicomponent samples may mutually interfere during analysis. Methods to resolve interferences are given in Section 6.

1.5 The values stated in SI units are to be regarded as the standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautions are given in 8.4, 9.2, and in A1.2.3.

Significance and Use

Promulgations by the Federal Occupational Safety and Health Administration (OSHA) in 29 CFR 1910 designate that certain organic compounds must not be present in workplace atmospheres at concentrations above specified values.

This practice, when used in conjunction with Practice D3686, will promote needed accuracy and precision in the determination of airborne concentrations of many of the organic chemicals given in 29 CFR 1910, CDC-99-74-45, NIOSH Manual of Analytical Methods, OSHA Sampling and Analytical Methods, HSE Methods for the Determination of Hazardous Substances, and BGIA GESTIS Analytical Methods. It can be used to determine worker exposures to these chemicals, provided appropriate sampling periods are used.

Most laboratories are equipped with apparatus similar to that described in Section 7. Other apparatus can be used when analytical procedures suitable for that equipment are employed. The analytical techniques (or variations thereof) described in Sections 9-11 are in general use to analyze volatile organic compounds extracted from charcoal. Other procedures can be used when appropriate.

Keywords

activated charcoal tube; air monitoring; charcoal tube; organic vapors; sampling and analysis; workplace atmospheres

To find similar documents by ASTM Volume:

11.07 (Atmospheric Analysis)

To find similar documents by classification:

13.040.20 (Ambient atmospheres Including indoor air)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D3687-07(2012)

Revision Level

2007 R12 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Aug. 1, 2012

Document Type

Practice

Page Count

6 pages

Committee Number

D22.04