ASTM-D3739 Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis

ASTM-D3739 - 2019 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
ORDER

Price:

$55.00        


Want this as a site license?

Scope

1.1 This practice covers the calculation and adjustment of the Langelier saturation index for the concentrate stream of a reverse osmosis (RO) device. This index is used to determine the need for calcium carbonate (CaCo3) scale control in the operation and design of RO installations. This practice is applicable for concentrate streams containing 10 to 10 000 mg/L of total dissolved solids. For concentrate containing over 10 000 mg/L, see Practice D4582.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 In the design and operation of RO installations, it is important to predict the calcium carbonate scaling properties of the concentrate stream. Because of the increase in total dissolved solids in the concentrate stream and the difference in passages for calcium ion, bicarbonate ion, and free carbon dioxide, the calcium carbonate scaling properties of the concentrate stream will generally be quite different from those of the feed solution. This practice permits the calculation of the Langelier saturation index for the concentrate stream from the feed water analyses and the RO operating parameters.

5.2 A positive Langelier saturation index indicates the tendency to form a calcium carbonate scale, which can be damaging to RO performance. This practice gives various procedures for the adjustment of the Langelier saturation index.

5.3 The tendency to form calcium carbonate scale can be suppressed by the addition of antiscalents or crystal modifiers. Suppliers of antisealents and crystal modifiers can provide information on the scale inhibition peformance of these types of chemical. Their use may be appropriate for reducing scale formation in RO systems. The RO system supplier should be consulted prior to the use of antisealents and crystal modifiers to ensure they will not have a negative impact on the RO system.

Keywords

CaCO3 scale; Langelier saturation index; LSI; reverse osmosis; scaling;

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

07.030 (Physics. Chemistry This group includes standards in the field of physics and chemistry as natural sciences Applied physics, see 17 Chemical technology, see 71)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D3739-19

Revision Level

2019 EDITION

Status

Current

Modification Type

Reinstated

Publication Date

July 1, 2019

Document Type

Practice

Page Count

4 pages

Committee Number

D19.08