ASTM-D3923 Historical Revision Information
Standard Practices for Detecting Leaks in Reverse Osmosis and Nanofiltration Devices

ASTM-D3923 - 2008 R14 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practices for Detecting Leaks in Reverse Osmosis and Nanofiltration Devices
ORDER

Scope

1.1 These practices cover detecting leaks in which there is a direct communication between the feed or concentrate, or both, and the permeate. Several types of leaks are possible with the various configurations of reverse-osmosis (RO) and nanofiltration (NF) devices.

1.2 Types of Leaks:

1.2.1 With hollow-fiber devices, feed or concentrate leakage, or both, into the permeate stream by leaks through the tube sheet and past the tube sheet O-ring are possible. “Leaks” caused by broken fibers are not covered by these practices.

1.2.2 With spiral-wound devices, leaks may occur through damage of the membrane surface itself by punctures or scratches, by glue-line failure, and by O-ring leaks on product tube interconnectors.

1.2.3 With tubular devices, leaks due to membrane damage, tube end seal leaks, and leaks from broken tubes or product headers are possible.

1.3 Three leak test practices are given as follows:

 

Sections

Practice A—Tube Sheet and O-Ring Leak Test for Hollow
 Fiber Devices

8 to 9

Practice B—Vacuum Test for Spiral Wound Devices

10 to 12

Practice C—Dye Test for Spiral Wound and Tubular Devices

13 to 18


1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

5.1 These practices may be used to determine whether a RO or NF device is free of leaks if the mechanical integrity of the device is to be confirmed. They may also be used to detect leaks in RO or NF devices whose operating performance indicates a possible leak. These practices may be used for either new or used devices.

Keywords

dye test; leaks; nanofiltration; O-ring test; reverse osmosis; tubesheet leak test; vacuum test

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

71.120.99 (Other equipment for the chemical industry)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D3923-08(2014)

Revision Level

2008 R14 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Feb. 15, 2014

Document Type

Practice

Page Count

3 pages

Committee Number

D19.08