ASTM-D4107 Historical Revision Information
Standard Test Method for Tritium in Drinking Water

ASTM-D4107 - 1998 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Tritium in Drinking Water
ORDER

Scope

1.1 This test method covers the determination of tritium in drinking water (as T2O or HTO) by liquid scintillation counting of the tritium beta particle activity.

1.2 This test method was used successfully with drinking water. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

1.3 The tritium concentrations which can be measured by this test method utilizing currently available liquid scintillation instruments, range from less than 0.037 Bq/mL (1 pCi/mL) to 555 Bq/mL (15000 pCi/mL) for a 10-mL sample aliquot. Higher tritium concentrations can be measured by diluting or using smaller sample aliquots, or both.

1.4 The maximum contaminant level for tritium in drinking water as given by the National Interim Primary Drinking Water Regulations (NIPDWR) is 0.740 Bq/mL (20000 pCi/L). The NIPDWR lists a required detection limit for tritium in drinking water of 0.037 Bq/mL (1 pCi/mL), meaning that drinking water supplies, where required, should be monitored for tritium at a sensitivity of 0.037 Bq/mL (1 pCi/mL). In Appendix X1, Eq X1.2 is given for determining the necessary counting time to meet the required sensitivity for drinking water monitoring.

1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Beta particle radioactivity; Contamination-water; Drinking water; H-3 tritium isotope; Liquid scintillation counting; Radioisotopes; Tritium; Water-radioactive analysis; tritium (T[inf]2[reset]O/HTO) in drinking water, test

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

13.060.50 (Examination of water for chemical substances)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D4107-98

Revision Level

1998 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

March 10, 1998

Document Type

Test Method

Page Count

4 pages

Committee Number

D19.04