ASTM-D4630 Historical Revision Information
Standard Test Method for Determining Transmissivity and Storage Coefficient of Low-Permeability Rocks by In Situ Measurements Using the Constant Head Injection Test (Withdrawn 2017)

ASTM-D4630 - 1996 R08 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Determining Transmissivity and Storage Coefficient of Low-Permeability Rocks by In Situ Measurements Using the Constant Head Injection Test
ORDER

Scope

1.1 This test method covers a field procedure for determining the transmissivity and storativity of geological formations having permeabilities lower than 103 μm2 (1 millidarcy) using constant head injection.

1.2 The transmissivity and storativity values determined by this test method provide a good approximation of the capacity of the zone of interest to transmit water, if the test intervals are representative of the entire zone and the surrounding rock is fully water-saturated.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Test MethodThe constant pressure injection test method is used to determine the transmissivity and storativity of low-permeability formations surrounding packed-off intervals. Advantages of the method are: (1) it avoids the effect of well-bore storage, (2) it may be employed over a wide range of rock mass permeabilities, and (3) it is considerably shorter in duration than the conventional pump and slug tests used in more permeable rocks.

AnalysisThe transient water flow rate data obtained using the suggested test method are evaluated by the curve-matching technique described by Jacob and Lohman (1) and extended to analysis of single fractures by Doe et al. (2). If the water flow rate attains steady state, it may be used to calculate the transmissivity of the test interval (3).

Units:

ConversionsThe permeability of a formation is often expressed in terms of the unit darcy. A porous medium has a permeability of 1 darcy when a fluid of viscosity 1 cp (1 mPa·s) flows through it at a rate of 1 cm3/s (106 m3/s)/1 cm2 (104 m2) cross-sectional area at a pressure differential of 1 atm (101.4 kPa)/1 cm (10 mm) of length. One darcy corresponds to 0.987 μm2. For water as the flowing fluid at 20°C, a hydraulic conductivity of 9.66 μm/s corresponds to a permeability of 1 darcy.

Keywords

Fault zones; Field testing--rock; Flow and flow rate--soil/rock/related materials; Permeability--soil/rock; Pressure testing--rock; Rock materials/properties/analysis; Saturation; Storativity; Transmissivity and reflectivity; Viscosity--rock; Water analysis; Water saturation; Borehole drilling; Constant head testing; Discontinuities--rock; ICS Number Code 07.060 (Geology. Meteorology. Hydrology)

To find similar documents by ASTM Volume:

04.08 (Soil and Rock (I): D420 - D5876)

To find similar documents by classification:

07.060 (Geology. Meteorology. Hydrology)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D4630-96(2008)

Revision Level

1996 R08 EDITION

Status

Superseded

Modification Type

Withdrawn

Publication Date

Oct. 1, 2008

Document Type

Test Method

Page Count

6 pages

Committee Number

D18.21