ASTM-D6617 › Historical Revision Information
Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This practice covers a methodology for establishing an acceptable tolerance zone for the difference between the result obtained from a single implementation of a test method on a Check Standard (CS) and its ARV, based on user-specified Type I error, the user-established test method precision, the standard error of the ARV, and a presumed hypothesis that the laboratory is performing the test method without bias.
1.2 For the tolerance zone established in 1.1, a methodology is presented to estimate the probability that the single test result will fall outside the zone, in the event that there is a bias (positive or negative) of a user-specified magnitude that is deemed to be of practical concern (that is, the presumed hypothesis is not true).
1.3 This practice is intended for ASTM Committee D02 test methods that produce results on a continuous numerical scale.
1.4 This practice assumes that the normal (Gaussian) model is adequate for the description and prediction of measurement system behavior when it is in a state of statistical control.
Significance and Use
4.1 Laboratories performing petroleum test methods can use this practice to set an acceptable tolerance zone for infrequent testing of CS or CCS material, based on ε, and a desired Type I error, for the purpose of ascertaining if the test method is being performed without bias.
4.2 This practice can be used to estimate the power of correctly detecting bias of different magnitudes, using the acceptable tolerance zone set in 4.1, and hence, gain insight into the limitation of the true bias detection capability associated with this acceptable tolerance zone. With this insight, trade-offs can be made between desired Type I error versus desired bias detection capability to suit specific business needs.
4.3 The CS testing activities described in this practice are intended to augment and not replace the regular statistical monitoring of test method performance as described in Practice D6299.
Keywords
accepted reference value; bias; check standard; consensus; power of test; probability of bias detection; type I error; type II error; ICS Number Code 19.020 (Test conditions and procedures in general)
To find similar documents by ASTM Volume:
05.03 (Petroleum Products and Lubricants (III): D6138 - D6971)
To find similar documents by classification:
19.020 (Test conditions and procedures in general)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.