Scope

1.1 This method is used to determine the concentration of available inorganic cyanide in an aqueous wastewater or effluent. The method detects the cyanides that are free (HCN and CN-) and metal-cyanide complexes that are easily dissociated into free cyanide ions. The method does not detect the less toxic strong metal-cyanide complexes, cyanides that are not “amenable to chlorination.”

1.2 Total cyanide can be determined for samples that have been distilled as described in Test Methods D2036, Test Method A, Total Cyanides after Distillation. The cyanide complexes are dissociated and absorbed into the sodium hydroxide capture solution, which can be analyzed with this test method; therefore, ligand exchange reagents from Sections 8.12 and 8.13 would not be required when determining total cyanide after distillation.

1.3 This procedure is applicable over a range of approximately 2 to 400 μg/L (parts per billion) available cyanides. Higher concentrations can be analyzed by dilution or lower injection volume.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 8.6 and Section 9.

Significance and Use

5.1 Cyanide and hydrogen cyanide are highly toxic. Regulations have been established to require the monitoring of cyanide in industrial and domestic wastes and surface waters.3

5.2 This test method is applicable for natural water, saline waters, metallurgical process solutions, and wastewater effluent.

5.3 The method may be used for process control in wastewater treatment facilities.

Keywords

amperometry; available cyanides; cyanide; cyanide amenable to chlorination; flow injection analysis; free cyanide; gas diffusion membrane; ligand exchange; silver electrode; weak acid dissociable cyanide;

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

17.120.10 (Flow in closed conduits Gas meters in buildings, see 91.140.40 Water meters in buildings, see 91.140.60)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D6888-16

Revision Level

2016 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

June 1, 2016

Document Type

Test Method

Page Count

8 pages

Committee Number

D19.06