ASTM-D6889 Historical Revision Information
Standard Practice for Fast Screening for Volatile Organic Compounds in Water Using Solid Phase Microextraction (SPME)

ASTM-D6889 - 2003 R11 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Fast Screening for Volatile Organic Compounds in Water Using Solid Phase Microextraction (SPME)
ORDER

Scope

1.1 This practice covers a procedure for the screening of trace levels of volatile organic compounds in water samples by headspace solid phase microextraction (SPME) in combination with fast gas chromatography with flame ionization detection.

1.2 The results from this screening procedure are used to estimate analyte concentrations to prevent contamination of purge and trap or headspace analytical systems.

1.3 The compounds of interest must have a greater affinity for the SPME absorbent polymer or adsorbent than the sample matrix or headspace phase in which they reside.

1.4 Not all of the analytes which can be determined by SPME are addressed in this practice. The applicability of the absorbent polymer, adsorbent or combination to extract the compound(s) of interest must be demonstrated before use.

1.5 Where used it is the responsibility of the user to validate the application of SPME to the analytes of interest.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.

Significance and Use

This practice provides a general procedure for the solid-phase microextraction (SPME) of volatile organic compounds from the headspace of an aqueous matrix. Absorbent extraction is used as the initial step in the extraction of organic constituents for the purpose of screening and subsequently estimating the concentration of the volatile organic components found in water samples. This information may then be used to determine whether a sample may be analyzed directly by purge and trap or headspace or will require dilution prior to analysis.

Typical detection limits that can be achieved using SPME techniques with gas chromatography (GC) with a flame ionization detector (FlD) range from milligrams per litre (mg/L) to micrograms per litre (μg/L). The detection limit, linear concentration range, and sensitivity of this test method for a specific organic compound will depend upon the aqueous matrix, the fiber phase, the sample temperature, sample volume, sample mixing, and the determinative technique employed.

Solid phase microextraction has the advantage of speed, reproducibility, simplicity, no solvent, small sample size, and automation.

Extraction devices vary from a manual SPME fiber holder to automated commercial devices specifically designed for SPME.

A partial list of volatile organic compounds that can be screened by this practice is shown in Table 1.

Keywords

screening ; solid phase microextraction; SPME; volatile; water; Contamination--water; Fast screening; Flame ionization detectors (FID); Gas chromatography (GC)--water; Headspace analysis; Purge sampling; Screen analysis--water; Solid phase microextraction (SPME); Trace elements--water analysis; Trap sampling; Volatile organic compounds (VOC)--water; ICS Number Code 13.060.50 (Examination of water for chemical substances)

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

13.060.50 (Examination of water for chemical substances)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D6889-03(2011)

Revision Level

2003 R11 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

June 15, 2011

Document Type

Practice

Page Count

5 pages

Committee Number

D19.06