Deriving Acceptable Levels of Airborne Chemical Contaminantsin Aircraft Cabins Based on H

ASTM-D7034 - 2011 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Deriving Acceptable Levels of Airborne Chemical Contaminants in Aircraft Cabins Based on Health and Comfort Considerations
ORDER

Scope

1.1 This guide provides methodology to assist in interpreting results of air quality measurements conducted in aircraft cabins. In particular, the guide describes methodology for deriving acceptable concentrations for airborne chemical contaminants, based on health and comfort considerations.

1.2 The procedures for deriving acceptable concentrations are based on considerations of comfort and health effects, including odor and irritant effects, of individual chemical contaminants being evaluated. The guide does not provide specific benchmark or guidance values for individual chemicals to compare with results of air quality measurements.

1.3 Chemical contaminant exposures under both routine and episodic conditions for passengers and crew are considered.

1.4 This guide does not address airborne microbiological contaminants, which are also important in consideration of aircraft cabin air quality. This guide also does not address methodologies for investigations of air quality complaints.

1.5 This guide assumes that a list of chemical contaminants of potential concern has been developed based on existing concentration, emission, or material composition data.

1.6 The primary information resources for developing acceptable concentrations are databases and documents maintained or published by cognizant authorities or organizations concerned with health effects of exposure to contaminants.

1.7 Acceptable concentrations developed through this guide may be used as a basis for selecting test methods with adequate reliability and sensitivity to assess the acceptability of aircraft cabin environments.

1.8 Procedures described in this guide should be carried out in consultation with qualified toxicologists and health effects specialists to ensure that acceptable concentrations developed are consistent with the current scientific understanding and knowledge base.

1.9 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Significance and Use

Although cabin air quality has been measured on numerous occasions and in many studies, there is very little guidance available for interpreting such data. Guidance for identifying contaminants and associated exposure levels that would cause concern in aircraft cabins is very limited. FAA Airworthiness Standards (14 CFR 25) constitute the only source of regulatory guidance that explicitly applies to the aircraft cabin environment. The FAA standards, however, define acceptable exposure limits for a limited number of chemical contaminants (ozone, carbon dioxide, and carbon monoxide). Another limitation of the FAA standards is that these are design standards only and are not operational standards; thus, once an aircraft is put in service these standards are not strictly applicable.

Measurements of aircraft cabin air quality often lead to a much larger list of volatile and semi-volatile organic chemicals of potential concern. Exposures to these chemicals, however, are largely unregulated outside of the industrial workplace.

An important feature of the aircraft cabin environment is that both passengers (public) and flight attendants (worker population) occupy it simultaneously. Therefore, workplace exposure guidelines cannot simply be extended to address exposures in aircraft cabin environment. Also, the length of flights and work shifts can vary considerably for flight attendants.

Contaminant levels of concern for the general public must account for the non-homogeneity of the population (for example, address sensitive individuals, the differences between passenger and crew activity levels, location, health status, personal microenvironment). Levels of concern associated with industrial workplace exposures typically consider a population of healthy adults exposed for 40 h per week (1). Consequently, exposure criteria developed to protect public health typically are more stringent than those for workers.

Given that the aircraft cabin environment must meet the needs of passengers as well as crew, a more stringent concentration level based upon the general population would protect both.

Aircraft cabin air quality must be addressed both during flight and on the ground because the conditions during flight are much different than when the aircraft is on the ground.

Keywords

airborne; chemical contaminants; aircraft cabins; health; comfort; ICS Number Code 49.095 (Passenger and cabin equipment)

To find similar documents by ASTM Volume:

11.07 (Atmospheric Analysis)

To find similar documents by classification:

49.095 (Passenger and cabin equipment)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D7034-11

Revision Level

2011 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

March 1, 2011

Document Type

Guide

Page Count

12 pages

Committee Number

D22.05