ASTM-E1008 Historical Revision Information
Installation, Inspection, & Maintenance of Valve-Body Pressure-Relief Methods for Geotherm

ASTM-E1008 - 2003 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This practice covers installation, inspection, and maintenance of valve body cavity pressure relief methods for valves used in geothermal and other high-temperature liquid service. The valve type covered by this practice is a design with an isolated body cavity such that when the valve is in either the open or closed position pressure is trapped in the isolated cavity, and there is no provision to relieve the excess pressure internally. The installation shall be such that direct access to the body cavity is maintained and that the pressure relief device may be periodically removed, cleaned, inspected, and reinstalled without endangering the operating personnel or removing the valve from its functional application. The relief device may be mounted with an automatic shutoff, such as a check valve held in the open position by the relief device. The shutoff device will not be rendered inoperative. The recommended procedures for winterizing valves shall be as follows: the valve must be fully closed or fully opened and the body cavity should be purged with a nonreactive gas (for example, nitrogen) or filled with a fluid to produce a solution with a low freezing point.

ORDER

Scope

1.1 This practice covers installation, inspection, and maintenance of valve body cavity pressure relief methods for valves used in geothermal and other high-temperature liquid service. The valve type covered by this practice is a design with an isolated body cavity such that when the valve is in either the open or closed position pressure is trapped in the isolated cavity, and there is no provision to relieve the excess pressure internally.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

geothermal valve; pressure-relief device

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

23.060.40 (Pressure regulators Including pressure-reducers Protection against excessive pressure, see 13.240)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1008-03

Revision Level

2003 EDITION

Status

Superseded

Modification Type

Revision with Title Change

Publication Date

Oct. 1, 2003

Document Type

Practice

Page Count

2 pages

Committee Number

E44.15