ASTM-E1026 Historical Revision Information
Standard Practice for Using the Fricke Dosimetry System

ASTM-E1026 - 1992 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Using the Fricke Dosimetry System
ORDER

Scope

1.1 This practice covers the preparation, testing and procedure for using the acidic aqueous ferrous ammonium sulfate solution dosimetry system to measure absorbed dose in water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the Fricke system. It is classified as a reference standard dosimeter (see Guide E1261).

1.2 The practice describes the spectrophotometric analysis procedures for the Fricke dosimeter.

1.3 This practice applies only to [gamma] rays, x rays, and high-energy electrons.

1.4 This practice applies provided the following are satisfied:

1.4.1 The absorbed dose range shall be from 40 to 400 Gy (1).

1.4.2 The absorbed dose rate shall not exceed 106 Gy[dot]s -1 (2).

1.4.3 For radioisotope gamma-ray sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be greater than 8 MeV (see ICRU Reports 34 and 35).

Note 1-The lower energy limits given are appropriate for a cylindrical dosimeter ampoule of 12 mm diameter. Corrections for dose gradients across an ampoule of that diameter or less are not required. The Fricke system may be used at lower energies by employing thinner (in the beam direction) dosimeter containers (see ICRU Report 35).

1.4.4 The irradiation temperature of the dosimeter should be within the range of 10 to 60°C.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Absorbed radiation dose; Dosimetry; Energy deposition-ionizing radiation; Fricke dosimeter; Reference standard dosimeter; Threshold detectors-1 to 30 MeV; Water-radioactive analysis; absorbed dose (of ionizing radiation) in water, using Fricke dosimeter,; method,; Ionizing radiation; absorbed dose (of ionizing radiation) in water, usingFricke dosimeter,; method; ICS Number Code 17.240 (Radiation measurements)

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1026-92

Revision Level

1992 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

May 15, 1992

Document Type

Practice

Page Count

7 pages

Committee Number

E61.02