ASTM-E1039 Historical Revision Information
Standard Test Method for Calibration of Silicon Non-Concentrator Photovoltaic Primary Reference Cells Under Global Irradiation (Withdrawn 2004)

ASTM-E1039 - 1985 R93(E1) EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Calibration of Silicon Non-Concentrator Photovoltaic Primary Reference Cells Under Global Irradiation (Withdrawn 2004)
ORDER

Scope

1.1 This test method is intended to be used for calibration and characterization of primary terrestrial, silicon photovoltaic reference cells to the global reference spectral irradiance distribution defined by Tables E892. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device.

1.2 Primary global reference cells are calibrated outdoors in natural sunlight by reference to a pyranometer that is used to measure the global irradiance.

1.3 This test method applies only to the calibration of a photovoltaic cell which demonstrates a linear short-circuit current versus irradiance characteristic over its intended range of use, as defined in Test Method E1143.

1.4 This test method applies only to the calibration of single- or poly-crystalline silicon reference cells that have been fabricated with a single photovoltaic junction.

1.5 There is no similar or equivalent ISO standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Calibration-nuclear analysis instrumentation; Characteristics/characterization; Current measurement-solar devices; Electrical performance-solar devices; Global irradiation; Irradiance/irradiation-solar; Nonconcentrator terrestrial photovoltaic reference cells; Photovoltaic power systems; Reference cells (for photovoltaic systems); Short circuit measurement; Solar collectors; Solar spectral irradiance; Spectral data-solar devices; Sunlight; calibration/characterization-non-concentrator photovoltaic reference; cells, under global irradiance, test

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

27.160 (Solar energy engineering Including photovoltaic energy systems)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1039-85(1993)e1

Revision Level

1985 R93(E1) EDITION

Status

Superseded

Modification Type

Withdrawn

Publication Date

June 1, 1993

Document Type

Test Method

Page Count

6 pages

Committee Number

E44.09