ASTM-E1707 Historical Revision Information
Estimating Uncertainties in Dosimetry for Radiation Processing, Standard Guide For

ASTM-E1707 - 1995 EDITION - SUPERSEDED -- See the following: ASTM-51707
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Estimating Uncertainties in Dosimetry for Radiation Processing (Withdrawn 2002)
ORDER

Scope

1.1 This guide defines possible sources of error in dosimetry performed in gamma, x-ray (bremsstrahlung) and electron irradiation facilities and offers procedures for estimating the resulting magnitude of the uncertainties in the measurement results. Basic concepts of measurement, estimate of the measured value of a quantity, "true" value, error and uncertainty are defined and discussed. Components of uncertainty are discussed and methods are given for evaluating and estimating their values. How these contribute to the standard uncertainty in the reported values of absorbed dose are considered and methods are given for calculating the combined standard uncertainty and an estimate of overall (expanded) uncertainty. The methodology for evaluating components of uncertainty follows ISO procedures (see 2.3). The traditional concepts of precision and bias are not used. Examples are given in five appendixes.

1.2 This guide assumes a working knowledge of statistics. Several statistical texts are included in the references (1, 2, 3, 4).

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Absorbed dose; Bremsstrahlung irradiation facilities; Dosimetry; Electron beam; Error analysis; Gamma radiation; Radiation processing; Uncertainty; X-ray processing; uncertainties in dosimetry-estimating for radiation processing, guide; ICS Number Code 17.240 (Radiation measurements)

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1707-95

Revision Level

1995 EDITION

Status

Superseded

Modification Type

Replaced

Publication Date

May 15, 1995

Document Type

Guide

Page Count

20 pages

Committee Number

E10.01