ASTM-E1897 Historical Revision Information
Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers

ASTM-E1897 - 2014 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers
ORDER

Scope

1.1 This practice covers procedures for measuring and compensating for transmittance when using an infrared imaging radiometer to measure the temperature of a specimen through an attenuating medium, such as a window, filter or atmosphere.2

1.2 The values stated in SI units are to be regarded as the standard.

1.3 These procedures may involve use of equipment and materials in the presence of heated or electrically-energized equipment, or both.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

5.1 The transmittance of an attenuating medium can cause errors for an infrared thermographer using an infrared imaging radiometer to measure the temperature of a specimen through the medium. Three test methods are given for measuring and compensating for this error source.

5.1.1 A procedure is given for measuring the transmittance of an attenuating medium.

5.1.2 A procedure is given for compensating for errors when measuring the temperature of a specimen having a known emissivity through an attenuating medium with a known transmittance.

5.1.3 A procedure is given for measuring and compensating for transmittance and emissivity errors when the specimen temperature is known.

5.2 These procedures can be used in the field or laboratory using commonly available materials.

5.3 These procedures can be used with any infrared radiometers that have the required computer capabilities.

5.4 The values of transmittance are defined only in terms of the procedure for the purpose of process control and nondestructive evaluation of materials.

Keywords

attenuating medium; blackbody simulator; emissivity; filter; imaging, infrared; infrared examination; infrared testing; infrared thermography; nondestructive testing; radiometry; reflected temperature; temperature compensation; transmittance; temperature measurement; window;; ICS Number Code 17.200.10 (Heat. Calorimetry)

To find similar documents by ASTM Volume:

03.03 (Nondestructive Testing)

To find similar documents by classification:

17.200.10 (Heat. Calorimetry)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1897-14

Revision Level

2014 EDITION

Status

Superseded

Modification Type

Revision with Title Change

Publication Date

Dec. 1, 2014

Document Type

Practice

Page Count

3 pages

Committee Number

E07.10