ASTM-E2033 Historical Revision Information
Standard Practice for Computed Radiology (Photostimulable Luminescence Method)

ASTM-E2033 - 1999 R13 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)
ORDER

Scope

1.1 This practice2 covers application details for computed radiology (CR) examination using a process in which photostimulable luminescence is emitted by the penetrating radiation detector, a storage phosphor imaging plate (SPIP). Because the techniques involved and the applications for CR examination are diverse, this practice is not intended to be limiting or restrictive, but rather to address the general applications of the technology and thereby facilitate its use. Refer to Guides E94 and E2007, Terminology E1316, and Practices E747 and E1025, and 21 CFR 1020.40 and 29 CFR 1910.96 for additional information and guidance.

1.2 The general principles discussed in this practice apply broadly to penetrating radiation CR systems. However, this document is written specifically for use with X-ray and gamma-ray systems. Other CR systems, such as those employing neutrons, will involve equipment and application details unique to such systems.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety statements, see Section 10 and 21 CFR 1020.40 and 29 CFR 1910.96.

Significance and Use

4.1 The X-, gamma-ray detector discussed in this practice is a storage phosphor imaging plate, hereafter referred to as SPIP. The SPIP, which is the key component in the CR process, differentiates CR from other radiologic methods. This practice is written so that it can be specified on the engineering drawing, specification, or contract and must be supplemented by a detailed procedure (see Section 6 and Annex A1 and Annex A2).

Keywords

analog; computed radiology; detector; digital; display; examination; image; processor; source; storage phosphor imaging plate; ICS Number Code 87.060.10 (Pigments and extenders)

To find similar documents by ASTM Volume:

03.03 (Nondestructive Testing)

To find similar documents by classification:

87.060.10 (Pigments and extenders)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E2033-99(2013)

Revision Level

1999 R13 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

June 15, 2013

Document Type

Practice

Page Count

11 pages

Committee Number

E07.01