ASTM-E2190 Historical Revision Information
Insulating Glass Unit Performance & Evaluation, Standard Specification For

ASTM-E2190 - 2008 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Specification for Insulating Glass Unit Performance and Evaluation
ORDER

Scope

1.1 This specification covers preassembled permanently sealed insulating glass units with one or two airspaces and preassembled insulating glass units with capillary tubes intentionally left open.

1.2 This specification is applicable only to sealed insulating glass units that are constructed with glass.

1.3 The qualification of test specimens is based on frost/dew point and on the absence of fog after the specified test durations.

1.4 Qualification under this specification is intended to provide a basis for evaluating the durability of sealed insulating glass units.

1.5 This specification is not applicable to sealed insulating glass units containing a spandrel glass coating due to test method limitations.

1.6 This specification does not cover other physical requirements such as appearance, thermophysical properties, heat and light transmission, and glass displacement.

Note 1—Sealed insulating glass units qualified according to this specification are not necessarily suitable for structurally glazed applications. Factors such as sealant longevity when exposed to long term ultraviolet light and the structural properties of the sealant must be reviewed for these applications. For more information on the requirements for structural sealant glazing applications, refer to Specification C 1369, Guide C 1249, and Test Method C 1265.

1.7 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only and are not considered standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

insulating glass units; seal durability; sealed insulating glass units; unit performance and evaluation; Building materials/applications--specifications; Performance--building materials/applications (specifications); Preassemble peermanently-sealed IGO; Sealed insulating glass units--specifications; Insulating glass (IG); ICS Number Code 81.040.20 (Glass in building)

To find similar documents by ASTM Volume:

04.12 (Building Constructions (II): E2112 - latest; Sustainability; Property Management Systems; Technology and Underground Utilities)

To find similar documents by classification:

81.040.20 (Glass in building)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E2190-08

Revision Level

2008 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Oct. 15, 2008

Document Type

Specification

Page Count

2 pages

Committee Number

E06.22