ASTM-E2190 Historical Revision Information
Insulating Glass Unit Performance & Evaluation, Standard Specification For

ASTM-E2190 - 2010 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Specification for Insulating Glass Unit Performance and Evaluation
ORDER

Scope

1.1 This specification covers preassembled permanently sealed insulating glass units with one or two airspaces and preassembled insulating glass units with capillary tubes intentionally left open.

1.2 This specification is applicable only to sealed insulating glass units that are constructed with glass.

1.3 This specification is applicable to both double-glazed and triple-glazed insulating glass units; for triple-glazed insulating glass units where both of the outer lites are glass and inner lite is either glass or a suspended film.

1.4 The qualification of test specimens is based on frost/dew point and on the absence of fog after the specified test durations.

1.5 The qualification of argon gas filled test specimens is based on the qualifications in 1.3 and maintaining the specified argon gas amounts before and after testing to Test Method E2188.

1.6 Qualification under this specification is intended to provide a basis for evaluating the durability of sealed insulating glass units.

1.7 This specification is not applicable to sealed insulating glass units containing a spandrel glass coating due to test method limitations.

1.8 This specification does not cover other physical requirements such as appearance, thermophysical properties, heat and light transmission, and glass displacement.

Note 1—Sealed insulating glass units qualified according to this specification are not necessarily suitable for structurally glazed applications. Factors such as sealant longevity when exposed to long term ultraviolet light and the structural properties of the sealant must be reviewed for these applications. For more information on the requirements for structural sealant glazing applications, refer to Specification C1369, Guide C1249, and Test Method C1265.

1.9 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

gas concentration; insulating glass units; seal durability; sealed insulating glass units; unit performance and evaluation; Building materials/applications--specifications; Insulating glass (IG); Performance--building materials/applications (specifications); Preassemble peermanently-sealed IGO; Sealed insulating glass units--specifications; ICS Number Code 81.040.20 (Glass in building)

To find similar documents by ASTM Volume:

04.12 (Building Constructions (II): E2112 - latest; Sustainability; Property Management Systems; Technology and Underground Utilities)

To find similar documents by classification:

81.040.20 (Glass in building)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E2190-10

Revision Level

2010 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Nov. 1, 2010

Document Type

Specification

Page Count

4 pages

Committee Number

E06.22