ASTM-E2322 Historical Revision Information
Standard Test Method for Conducting Traverse and Concentrated Load Tests on Panels used in Floor and Roof Construction

ASTM-E2322 - 2003 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Conducting Transverse and Concentrated Load Tests on Panels used in Floor and Roof Construction
ORDER

Scope

1.1 These test methods cover the following procedures for determining the structural properties of segments of floor and roof constructions:

SectionTest SpecimensLoadingDeformation MeasurementsReportPrecision and BiasTesting FloorsTransverse LoadConcentrated LoadTesting RoofsTransverse LoadConcentrated Load

1.2 Metric units (SI) are to be considered as the primary standard units.

1.3 These test methods serve to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing and/or supporting members (floor joist, rafters and trusses).

1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.

1.5 This standard is not intended to cover concrete floor slabs.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Transverse LoadThe procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.

Concentrated LoadThis concentrated load test shall be used to evaluate surface indentation of structural framing members.

These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Method E 455. Impact loading shall be evaluated under Test Methods E 661 or E 695.

Keywords

concentrated loads; deformation; floors; load duration; roofs; sheathing; strength tests; transverse loads; ICS Number Code 91.060.30 (Ceilings. Floors. Stairs)

To find similar documents by ASTM Volume:

04.12 (Building Constructions (II): E2112 - latest; Sustainability; Property Management Systems; Technology and Underground Utilities)

To find similar documents by classification:

91.060.30 (Ceilings. Floors. Stairs Including screeds, ramps, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E2322-03

Revision Level

2003 EDITION

Status

Superseded

Modification Type

New

Publication Date

Oct. 1, 2003

Document Type

Test Method

Page Count

6 pages

Committee Number

E06.11