ASTM-E2322 › Historical Revision Information
Standard Test Method for Conducting Traverse and Concentrated Load Tests on Panels used in Floor and Roof Construction
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method covers the following procedures for determining the structural properties of segments of floor and roof constructions:
Section | |
Test Specimens | 5 |
Loading | 6 |
Deformation Measurements | 7 |
Report | 9 |
Precision and Bias | 10 |
Testing Floors | |
Transverse Load | 11 |
Concentrated Load | 12 |
Testing Roofs | |
Transverse Load | 13 |
Concentrated Load | 14 |
1.2 This test method serves to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing or supporting members (floor joist, rafters, and trusses), or both.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.
1.4 This standard is not intended to cover concrete floor slabs.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use
Transverse Load—The procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.
Concentrated Load—This concentrated load test shall be used to evaluate surface indentation of structural framing members.
These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Test Method E 455
Keywords
concentrated loads; deformation; floors; load duration; roofs; sheathing; strength tests; transverse loads; Concentrated loading tests; Deformation; Flooring/floor covering systems; Loading tests--flooring; Loading tests--roofing materials; Roofing materials/applications; Sheaths/sheathing; Strength--roofing materials/applications; Transverse load-bearing materials/applications; ICS Number Code 91.060.30 (Ceilings. Floors. Stairs)
To find similar documents by ASTM Volume:
To find similar documents by classification:
91.060.30 (Ceilings. Floors. Stairs Including screeds, ramps, etc.)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-E2322-03(2009)
Revision Level
2003 R09 EDITION
Status
Superseded
Modification Type
Reapproval
Publication Date
May 1, 2009
Document Type
Test Method
Page Count
6 pages
Committee Number