ASTM-E607 Historical Revision Information
Standard Test Method for Atomic Emission Spectrometric Analysis Aluminum Alloys by the Point to Plane Technique Nitrogen Atmosphere

ASTM-E607 - 2002 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Atomic Emission Spectrometric Analysis Aluminum Alloys by the Point to Plane Technique Nitrogen Atmosphere
ORDER

Scope

1.1 This test method covers the spectrochemical analysis of aluminum and aluminum alloys for the following elements in the concentration ranges indicated:

ElementConcentration Range, %
Silicon0.001 to 23.0
Copper0.001 to 20.0
Magnesium0.001 to 11.0
Zinc0.001 to 10.0
Tin0.001 to 7.5
Nickel0.001 to 4.0
Iron0.001 to 3.0
Lithium0.0001 to 3.0
Cobalt0.001 to 2.0
Manganese0.001 to 2.0
Chromium0.001 to 1.0
Silver0.001 to 1.0
Zirconium0.001 to 1.0
Lead0.002 to 0.7
Bismuth0.001 to 0.7
Cadmium0.001 to 0.5
Titanium0.001 to 0.5
Beryllium0.0001 to 0.5
Vanadium0.001 to 0.15
Calcium0.001 to 0.05
Gallium0.001 to 0.05
Boron0.0001 to 0.05
Sodium0.0001 to 0.05

1.2 The test method is applicable primarily to the control analysis of chill-cast samples. Other forms may be analyzed, provided that (1) they are sufficiently massive to prevent undue heating; (2) they permit machining flat surfaces having a minimum dimension of approximately 30 by 30 mm (1.2 in. by 1.2 in.); and (3) reference materials of similar metallurgical condition and chemical composition are available.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This test method is suitable for manufacturing control, for material or product acceptance, and for research and development. Its use over several years has shown precision and accuracy that are well within expected levels.

It is assumed that all who use this test method will be trained analysts capable of performing laboratory procedures skillfully and safely, and that the work will be performed in a properly equipped laboratory.

Keywords

spectrochemical analysis; aluminum; aluminum alloys; chill-cast; ICS Number Code 77.120.10 (Aluminium and aluminium alloys)

To find similar documents by ASTM Volume:

03.05 (Analytical Chemistry for Metals, Ores, and Related Materials: E 32 - latest)

To find similar documents by classification:

77.120.10 (Aluminium and aluminium alloys)

To find similar documents by Federal Supply Class Code:

FSC Standardization Area NDTI (Nondestructive Testing and Inspection)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E607-02

Revision Level

2002 EDITION

Status

Superseded

Modification Type

Withdrawn

Publication Date

Oct. 10, 2002

Document Type

Test Method

Page Count

9 pages

Committee Number

E01.04