Scope
1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure.
1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions.
1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution.
1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest.
1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Reference Spectral Irradiance Distribution | Total Irradiance (Wm−2) | Temperature (°C) |
---|---|---|
Tables G 173 | 1000 | 25 |
Tables G 173 | 1000 | 25 |
Tables E 490 | 1366.1 | 25 |
Significance and Use
It is the intent of this test method to provide a recognized method for testing and reporting the electrical performance of photovoltaic cells.
The test results may be used for comparison of cells among a group of similar cells or to compare diverse designs, such as different manufacturers' products. Repeated measurements of the same cell may be used to study changes in device performance.
This test method determines the electrical performance of a cell based upon the output power at a single instant of time. It does not provide for integrating the output power over a given period of time and conditions to predict an energy output.
This test method requires a reference cell calibrated with respect to an appropriate reference spectral irradiance distribution, such as Tables E 490
Keywords
cell; performance; photovoltaic; testing; Current measurement--solar devices; Electrical performance--solar devices; Photovoltaic (PV) power systems; Solar collectors; Solar spectral irradiance; Voltage; ICS Number Code 27.160 (Solar energy engineering)
To find similar documents by ASTM Volume:
12.02 (Nuclear (II), Solar, and Geothermal Energy)
To find similar documents by classification:
27.160 (Solar energy engineering Including photovoltaic energy systems)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-E948-09
Revision Level
2009 EDITION
Status
Superseded
Modification Type
Revision
Publication Date
April 1, 2009
Document Type
Test Method
Page Count
6 pages
Committee Number
E44.09