Scope
1.1 This safety specification establishes requirements for devices intended to address the risk of injury and death associated with accidental falls through open windows by children five years old and younger.
Note 1—This specification is not intended to meet the unique requirements of Americans With Disabilities Act (ADA).
1.2 This safety specification applies only to window fall prevention devices, including window opening control devices, window fall prevention screens, and fall prevention window guards that are to be used on windows that are not intended for escape (egress) and rescue (ingress).
Note 2—Specification F 2090
1.3 This safety specification applies only to devices intended to be applied to windows installed at heights of more than 75 ft (23 m) above ground level in multiple family dwelling buildings. This safety specification is not intended to apply to windows below 75 ft (23 m) because all windows below 75 ft (23 m) that are operable could be used as a possible secondary means of escape.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.
Keywords
fall prevention window guards; falls; safety standard; window fall prevention devices; window fall prevention screens; window opening control devices; windows; Accidental falls; Consumer safety specifications; Fall protection materials/applications; Nonemergency escape (egress) windows; Rescue (ingress) windows; Safety precautions--consumer materials/applications; Window fall prevention devices; Windows/window assemblies--specifications; ICS Number Code 13.200 (Accident and disaster control); 91.060.50 (Doors and windows)
To find similar documents by ASTM Volume:
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-F2006-08
Revision Level
2008 EDITION
Status
Superseded
Modification Type
Revision
Publication Date
Nov. 1, 2008
Document Type
Specification
Page Count
10 pages
Committee Number
F15.38