ASTM-F2592 Historical Revision Information
Standard Test Method for Measuring the Force-Displacement of a Membrane Switch

ASTM-F2592 - 2007A EDITION - SUPERSEDED -- See the following: ASTM-F1997
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Measuring the Force-Displacement of a Membrane Switch (Withdrawn 2023)
ORDER

Scope

1.1 This test method covers the measurement of force displacement characteristics of a membrane switch.

1.1.1 This test method replaces Test Method F 1570. The Tactile Response Slope has been determined to be a more representative characterization of a tactile sensation.

1.1.2 This test method replaces Test Method F 1682.

1.1.3 This test method replaces Test Method F 1597.

1.1.4 This test method replaces Test Method F 1997.

1.2 Force displacement hysterisis loop curve can be used in the determination of Actuation Force, Displacement, Contact Force, Return Force, and Tactile Response Slope.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

The force and displacement values when converted to a slope are useful in quantifying the differences in tactile response among membrane switches.

Specified resistance is useful to manufacturers and users when designing membrane switch interface circuitry.

Actuation force and contact force are useful to manufacturers and users in determining the suitability, reference and aesthetics of a membrane switch in a given application.

The tendency of a switch to make or break electrical contact at unexpected moments during closure or release can be a sign of a poor design. The degree of teasing can range from a simple annoyance to a failure of critical control process.

The amount of switch sensitivity or teasing can also be a result of poor surface conductivity that will prevent an electrical event even when switch poles are in partial contact.

Keywords

force-displacement curve; membrane switch; tactile recovery slope; tactile response slope; travel; ICS Number Code 29.120.40 (Switches)

To find similar documents by ASTM Volume:

10.04 (Electronics; Declarable Substances in Materials; 3D Imaging Systems)

To find similar documents by classification:

29.120.40 (Switches)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-F2592-07a

Revision Level

2007A EDITION

Status

Superseded

Modification Type

Revision

Publication Date

July 1, 2007

Document Type

Test Method

Page Count

5 pages

Committee Number

F01.18