SS-EN-ISO-80601-2-61 Historical Revision Information
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO 80601-2-61:2011)

SS-EN-ISO-80601-2-61 - 2011 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of PULSE OXIMETER EQUIPMENT intended for use on humans, hereafter referred to as ME EQUIPMENT. This includes any part necessary for NORMAL USE, including the PULSE OXIMETER MONITOR, PULSE OXIMETER PROBE, and PROBE CABLE EXTENDER. These requirements also apply to PULSE OXIMETER EQUIPMENT, including PULSE OXIMETER MONITORS, PULSE OXIMETER PROBES and PROBE CABLE EXTENDERS, which have been REPROCESSED. The intended use of PULSE OXIMETER EQUIPMENT includes, but is not limited to, the estimation of arterial oxygen haemoglobin saturation and pulse rate of PATIENTS in professional healthcare institutions as well as PATIENTS in the HOME HEALTHCARE ENVIRONMENT. This International Standard is not applicable to PULSE OXIMETER EQUIPMENT intended for use in laboratory research applications nor to oximeters that require a blood sample from the PATIENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 201.11 and in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This standard can also be applied to PULSE OXIMETER EQUIPMENT and their ACCESSORIES used for compensation or alleviation of disease, injury or disability. This International Standard is not applicable to PULSE OXIMETER EQUIPMENT intended solely for foetal use. This International Standard is not applicable to remote or slave (secondary) devices that display SpO2 values that are located outside of the PATIENT ENVIRONMENT.

To find similar documents by classification:

11.040.10 (Anaesthetic, respiratory and reanimation equipment Including medical gas installations)

11.040.55 (Diagnostic equipment Including medical monitoring equipment, medical thermometers and related materials)


Medical devices

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

ORDER



Designation Name

SS-EN ISO 80601-2-61:2011

Revision Level

2011 EDITION

Status

Superseded

Publication Date

April 19, 2011

Language(s)

English

Page Count

104

International Equivalent

EN ISO 80601-2-61:2011(IDT); ISO 80601-2-61:2011(IDT)